Biomechanical Stress Analysis of Overdentures Supported and Retained by Peek Implants and Attachments Using Different Designs : A 3D Finite Element Analysis Study

Background: Analysis of stresses induced by using poly ether ether ketone (PEEK) implants and prosthetic attachments for implant supported mandibular complete overdenture. Methods: 3D finite element model was made for lower complete overdenture, supported by implants (4 mm in diameter, 12 mm in length) and retained by ball attachments. Linear static stress analysis was carried out by ANSYS 2020. Three model cases were created. Model 1 supported by two Ti implants in canine region, Model 2 supported by three PEEK implants (2 in canine region, 1 in midline), Model 3 supported by 4 PEEK implants bilaterally in canine and premolar region. Same material either titanium alloy or PEEK was used in modelling all prosthetic components in each case model. Application of force (120 N) bilaterally was carried out 3 times for each model case (vertical, oblique and lateral). Results: Model 3 showed the highest maximum and minimum principal stresses, in peri-implant cortical bone and exceeded its tensile and compressive yield strength after lateral loading. In model 2 Cortical bone Maximum and minimum principal stresses did not exceed its yield strength, in the three loading scenarios. However, cortical bone tensile stresses labial to midline implant in model 2 showed low safety factor. Conclusions: Model 2 design can be promising biomechanically, if used in normal density bone, but with caution against the critical high tensile stresses at the cortical bone labial to midline implant. While model 3 design could result in excessive high stresses leading to yielding and resorption of cortical bone.

Authors

Institutions

Publication Details

Journal
Egyptian Dental Journal /Egyptian Dental Journal
Published
2025-01-01
DOI
https://doi.org/10.21608/edj.2024.317878.3196
Primary Topic
Surgical Sutures and Adhesives
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical Stress Analysis of Overdentures Supported and Retained by Peek Implants and Attachments Using Different Designs : A 3D Finite Element Analysis Study

Reem Ashraf, Shadia Elsayed, Yousra Ahmed, Mohamed I. El-Anwar et al.
Egyptian Dental Journal /Egyptian Dental Journal
Surgical Sutures and Adhesives
article

Biomechanical Stress Analysis of Overdentures Supported and Retained by Peek Implants and Attachments Using Different Designs : A 3D Finite Element Analysis Study

Reem Ashraf, Shadia Elsayed, Yousra Ahmed, Mohamed I. El-Anwar, enas elddamony
article en

Abstract

Background: Analysis of stresses induced by using poly ether ether ketone (PEEK) implants and prosthetic attachments for implant supported mandibular complete overdenture. Methods: 3D finite element model was made for lower complete overdenture, supported by implants (4 mm in diameter, 12 mm in length) and retained by ball attachments. Linear static stress analysis was carried out by ANSYS 2020. Three model cases were created. Model 1 supported by two Ti implants in canine region, Model 2 supported by three PEEK implants (2 in canine region, 1 in midline), Model 3 supported by 4 PEEK implants bilaterally in canine and premolar region. Same material either titanium alloy or PEEK was used in modelling all prosthetic components in each case model. Application of force (120 N) bilaterally was carried out 3 times for each model case (vertical, oblique and lateral). Results: Model 3 showed the highest maximum and minimum principal stresses, in peri-implant cortical bone and exceeded its tensile and compressive yield strength after lateral loading. In model 2 Cortical bone Maximum and minimum principal stresses did not exceed its yield strength, in the three loading scenarios. However, cortical bone tensile stresses labial to midline implant in model 2 showed low safety factor. Conclusions: Model 2 design can be promising biomechanically, if used in normal density bone, but with caution against the critical high tensile stresses at the cortical bone labial to midline implant. While model 3 design could result in excessive high stresses leading to yielding and resorption of cortical bone.

Egyptian Dental Journal /Egyptian Dental JournalVol. 71(1)
Suez Canal University (EG), National Research Centre (EG)
Openalex Percentile: Top 99%
Surgical Sutures and Adhesives
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.