Assessment of Marginal Integrity and Fracture Resistance of Nanographene-Reinforced Polymethyl Methacrylate Versus Conventional Polymethyl Methacrylate Single Crowns

Problem: CAD/CAM PMMA, as a provisional material, needs physical, mechanical, and biological improvements. Purpose: To compare graphene-reinforced PMMA crowns' marginal adaption and fracture resistance to CAD/CAM PMMA crowns under simulated oral conditions. Methods: A typodont mandibular first molar was prepared for an all-ceramic crown. Duplicating it yielded 20 dental epoxy resin dies. A 3D scanning was performed for each die to design 20 crowns. Ten crowns were milled from PMMA blanks (P) and 10 from graphene-reinforced PMMA blanks (G). Next, resin cement luted each crown to its die. Each specimen was digitally imaged for marginal gap assessment. Four equidistant landmarks at each specimen's cervical circumference were measured. A chewing simulator aged tested crowns for 120,000 cycles. The marginal gap evaluation was repeated after aging. Each crown was evaluated for fracture resistance in a universal testing machine that determined fracture load in Newton. All data were statistically analyzed. Results: The tested materials did not differ statistically before or after thermocycling. Group (P) showed no statistically significant difference in mean gap distance after thermocycling, while Group (G) showed a statistically significant rise (P-value = 0.033, Effect size = 0.719). The fracture resistance of the two groups was not significantly different (P-value = 0.839, Effect size = 0.132). Conclusions: The mean marginal gap between PMMA and G-PMMA was clinically acceptable. Neither material fractured beyond posterior maximal masticatory stresses, demonstrating clinical resistance. The clinical uses of graphene-reinforced PMMAs are similar to CAD/CAM PMMAs, considering them effective long-term interim materials rather than permanent restorative alternatives.

Authors

Institutions

Publication Details

Journal
Egyptian Dental Journal /Egyptian Dental Journal
Published
2025-01-01
DOI
https://doi.org/10.21608/edj.2024.333023.3251
Citations
1
Primary Topic
Tribology and Wear Analysis
Type
article
Field-Weighted Citation Impact
0.86
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of Marginal Integrity and Fracture Resistance of Nanographene-Reinforced Polymethyl Methacrylate Versus Conventional Polymethyl Methacrylate Single Crowns

Marwa Beleidy, Кhaled Elbanna, Ahmed Ziada
1 citations
Egyptian Dental Journal /Egyptian Dental Journal
Tribology and Wear Analysis
0.86
article

Assessment of Marginal Integrity and Fracture Resistance of Nanographene-Reinforced Polymethyl Methacrylate Versus Conventional Polymethyl Methacrylate Single Crowns

Marwa Beleidy, Кhaled Elbanna, Ahmed Ziada
article en
1 citations

Abstract

Problem: CAD/CAM PMMA, as a provisional material, needs physical, mechanical, and biological improvements. Purpose: To compare graphene-reinforced PMMA crowns' marginal adaption and fracture resistance to CAD/CAM PMMA crowns under simulated oral conditions. Methods: A typodont mandibular first molar was prepared for an all-ceramic crown. Duplicating it yielded 20 dental epoxy resin dies. A 3D scanning was performed for each die to design 20 crowns. Ten crowns were milled from PMMA blanks (P) and 10 from graphene-reinforced PMMA blanks (G). Next, resin cement luted each crown to its die. Each specimen was digitally imaged for marginal gap assessment. Four equidistant landmarks at each specimen's cervical circumference were measured. A chewing simulator aged tested crowns for 120,000 cycles. The marginal gap evaluation was repeated after aging. Each crown was evaluated for fracture resistance in a universal testing machine that determined fracture load in Newton. All data were statistically analyzed. Results: The tested materials did not differ statistically before or after thermocycling. Group (P) showed no statistically significant difference in mean gap distance after thermocycling, while Group (G) showed a statistically significant rise (P-value = 0.033, Effect size = 0.719). The fracture resistance of the two groups was not significantly different (P-value = 0.839, Effect size = 0.132). Conclusions: The mean marginal gap between PMMA and G-PMMA was clinically acceptable. Neither material fractured beyond posterior maximal masticatory stresses, demonstrating clinical resistance. The clinical uses of graphene-reinforced PMMAs are similar to CAD/CAM PMMAs, considering them effective long-term interim materials rather than permanent restorative alternatives.

Egyptian Dental Journal /Egyptian Dental JournalVol. 71(1)
Beni-Suef University (EG), Umm al-Qura University (SA), October 6 University (EG)
Openalex Percentile: Top 36%
Tribology and Wear Analysis
0.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.