Comparison between sonographic features using TIRADS criteria and fine needle aspiration cytology in the diagnosis of solitary and dominant thyroid nodule

Background: The accuracy of both the Thyroid Imaging Reporting and Data Systems (TIRADS) staging system and fine needle aspiration cytology (FNAC) for the diagnosis of malignant thyroid nodules remains controversial.Objective: The aim of this study was to compare the utility of sonographic features using TIRADS criteria versus FNAC in the diagnosis of solitary and dominant thyroid nodules.Methods: This cross-sectional study enrolled patients with solitary or dominant thyroid nodules of both sexes. Patient data were obtained from their medical records. Thyroid ultrasound characteristics, FNAC, and cell block slides were reviewed. The TIRADs approach and the Bethesda system were used to categorize thyroid lesions. The receiver operating characteristic curve was performed on all radiological and pathological findings. Results: The study included 158 patients with solitary or dominant thyroid nodules. TIRADS was significantly associated with Bethesda diagnoses and the histopathological diagnosis of malignant thyroid nodules (p<0.001). At a cutoff of ≥3, the TIRADS showed significantly good discrimination between malignant and benign nodules (AUC=0.842, p<0.001). At a cutoff ≥II, Bethesda showed a significant fair power of diagnosis of malignant nodules (AUC=0.784, p<0.001). The overall accuracy of Bethesda was slightly higher compared to TIRADS. There was a significantly poor concordance between TIRADS and Bethesda classification systems (weighted kappa =0.186, 95% CI: 0.117 to 0.255, p<0.001).Conclusion: In patients with solitary and dominant thyroid nodules, there is a poor diagnostic correlation between TIRADS and Bethesda classification systems. However, the overall accuracy of Bethesda was slightly higher than that of TIRADS.

Authors

Institutions

Publication Details

Journal
The Egyptian Journal of Surgery
Published
2025-01-01
DOI
https://doi.org/10.21608/ejsur.2024.316698.1182
Primary Topic
Thyroid Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison between sonographic features using TIRADS criteria and fine needle aspiration cytology in the diagnosis of solitary and dominant thyroid nodule

Osama Refaie Mohamed, Esraa Ramadan Gaballah, Ahmed M. Moustafa, Abdelhay A. Abdelhay et al.
The Egyptian Journal of Surgery
Thyroid Cancer Diagnosis and Treatment
article

Comparison between sonographic features using TIRADS criteria and fine needle aspiration cytology in the diagnosis of solitary and dominant thyroid nodule

Osama Refaie Mohamed, Esraa Ramadan Gaballah, Ahmed M. Moustafa, Abdelhay A. Abdelhay, Ahmed Awad
article en

Abstract

Background: The accuracy of both the Thyroid Imaging Reporting and Data Systems (TIRADS) staging system and fine needle aspiration cytology (FNAC) for the diagnosis of malignant thyroid nodules remains controversial.Objective: The aim of this study was to compare the utility of sonographic features using TIRADS criteria versus FNAC in the diagnosis of solitary and dominant thyroid nodules.Methods: This cross-sectional study enrolled patients with solitary or dominant thyroid nodules of both sexes. Patient data were obtained from their medical records. Thyroid ultrasound characteristics, FNAC, and cell block slides were reviewed. The TIRADs approach and the Bethesda system were used to categorize thyroid lesions. The receiver operating characteristic curve was performed on all radiological and pathological findings. Results: The study included 158 patients with solitary or dominant thyroid nodules. TIRADS was significantly associated with Bethesda diagnoses and the histopathological diagnosis of malignant thyroid nodules (p<0.001). At a cutoff of ≥3, the TIRADS showed significantly good discrimination between malignant and benign nodules (AUC=0.842, p<0.001). At a cutoff ≥II, Bethesda showed a significant fair power of diagnosis of malignant nodules (AUC=0.784, p<0.001). The overall accuracy of Bethesda was slightly higher compared to TIRADS. There was a significantly poor concordance between TIRADS and Bethesda classification systems (weighted kappa =0.186, 95% CI: 0.117 to 0.255, p<0.001).Conclusion: In patients with solitary and dominant thyroid nodules, there is a poor diagnostic correlation between TIRADS and Bethesda classification systems. However, the overall accuracy of Bethesda was slightly higher than that of TIRADS.

The Egyptian Journal of SurgeryVol. 44(1)
Cairo University (EG)
Zero hunger
Openalex Percentile: Top 99%
Thyroid Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison between sonographic features using TIRADS criteria and fine needle aspiration cytology in the diagnosis of solitary and dominant thyroid nodule — Osama Refaie Mohamed, Esraa Ramadan Gaballah, et al. · The Egyptian Journal of Surgery (2025) | TGRS Research Map | TGRS