External DC Shocks of Symptomatic Supraventricular Tachycardia During Screw‐In Leadless Pacemaker Implant: A Case Report

We present the case of a 64-year-old man who, during the implantation of an active-fixation leadless pacemaker (LP, Aveir VR, Abbott, USA), underwent several external defibrillation shocks up to 240 Joules, due to symptomatic sustained supraventricular tachycardia at 160 bpm. The shocks, delivered both before and after the screwing of the device in the low interventricular septum, did not cause any technical damage to the device, and no complications were observed. The device was then deployed successfully. To our knowledge, this is the first documented case of external cardioversion (ECV) in a patient with an active-fixation LP. The results suggest that ECV in these patients appears to be safe and feasible.

Authors

Institutions

Publication Details

Journal
Pacing and Clinical Electrophysiology
Published
2025-01-10
DOI
https://doi.org/10.1111/pace.15134
Citations
1
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
1.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

External DC Shocks of Symptomatic Supraventricular Tachycardia During Screw‐In Leadless Pacemaker Implant: A Case Report

Ersilia Cipolletta, Giovanni Napolitano, Emma Arezzi, Mattia Liccardo et al.
1 citations
Pacing and Clinical Electrophysiology
Cardiac pacing and defibrillation studies
1.39
article

External DC Shocks of Symptomatic Supraventricular Tachycardia During Screw‐In Leadless Pacemaker Implant: A Case Report

Ersilia Cipolletta, Giovanni Napolitano, Emma Arezzi, Mattia Liccardo, Monica Sicuranza, Maria Rea, Pietro Ricciardi
article en
1 citations

Abstract

We present the case of a 64-year-old man who, during the implantation of an active-fixation leadless pacemaker (LP, Aveir VR, Abbott, USA), underwent several external defibrillation shocks up to 240 Joules, due to symptomatic sustained supraventricular tachycardia at 160 bpm. The shocks, delivered both before and after the screwing of the device in the low interventricular septum, did not cause any technical damage to the device, and no complications were observed. The device was then deployed successfully. To our knowledge, this is the first documented case of external cardioversion (ECV) in a patient with an active-fixation LP. The results suggest that ECV in these patients appears to be safe and feasible.

Pacing and Clinical ElectrophysiologyVol. 48(3)
Aeromechs (Italy) (IT), Marzano Research (United States) (US), Bouty (Italy) (IT)
Good health and well-being
Openalex Percentile: Top 24%
Cardiac pacing and defibrillation studies
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.