Arthroscopy is a minimally invasive surgical procedure used to diagnose and treat joint problems. The clinical workflow of arthroscopy typically involves inserting an arthroscope into the joint through a small incision, during which surgeons navigate and operate largely by relying on their visual assessment through the arthroscope. However, the arthroscope's restricted field of view and lack of depth perception pose challenges in navigating complex articular structures and achieving surgical precision during procedures. Aiming at enhancing intraoperative awareness, a robust pipeline that incorporates simultaneous localization and mapping, depth estimation, and 3D Gaussian splatting (3D GS) is presented to realistically reconstruct intra-articular structures solely based on monocular arthroscope video. Extending 3D reconstruction to augmented reality (AR) applications, the solution offers AR assistance for articular notch measurement and annotation anchoring in a human-in-the-loop manner. Compared to traditional structure-from-motion and neural radiance field-based methods, the pipeline achieves dense 3D reconstruction and competitive rendering fidelity with explicit 3D representation in 7 min on average. When evaluated on four phantom datasets, our method achieves root-mean-square-error <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow><mml:mrow><mml:mtext>(RMSE)</mml:mtext> <mml:mo>=</mml:mo> <mml:mn>2.21</mml:mn> <mml:mspace></mml:mspace> <mml:mtext>mm</mml:mtext></mml:mrow> </mml:mrow> </mml:math> reconstruction error, peak signal-to-noise ratio <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow><mml:mrow><mml:mtext>(PSNR)</mml:mtext> <mml:mo>=</mml:mo> <mml:mn>32.86</mml:mn></mml:mrow> </mml:mrow> </mml:math> and structure similarity index measure <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow><mml:mrow><mml:mtext>(SSIM)</mml:mtext> <mml:mo>=</mml:mo> <mml:mn>0.89</mml:mn></mml:mrow> </mml:mrow> </mml:math> on average. Because the pipeline enables AR reconstruction and guidance directly from monocular arthroscopy without any additional data and/or hardware, the solution may hold the potential for enhancing intraoperative awareness and facilitating surgical precision in arthroscopy. The AR measurement tool achieves accuracy within <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow><mml:mrow><mml:mn>1.59</mml:mn> <mml:mo>±</mml:mo> <mml:mn>1.81</mml:mn> <mml:mspace></mml:mspace> <mml:mtext>mm</mml:mtext></mml:mrow> </mml:mrow> </mml:math> and the AR annotation tool achieves a mIoU of 0.721.

Authors

Institutions

Publication Details

Journal
Healthcare Technology Letters
Published
2025-01-01
DOI
https://doi.org/10.1049/htl2.12119
Citations
2
Primary Topic
Robotics and Sensor-Based Localization
Type
article
Field-Weighted Citation Impact
9.99

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seamless augmented reality integration in arthroscopy: a pipeline for articular reconstruction and guidance

Russell H. Taylor, Jonathan Knopf, M. Liu, Hongchao Shu et al.
2 citations
Healthcare Technology Letters
Robotics and Sensor-Based Localization
9.99
article

Seamless augmented reality integration in arthroscopy: a pipeline for articular reconstruction and guidance

Russell H. Taylor, Jonathan Knopf, M. Liu, Hongchao Shu, Mathias Unberath, Ping‐Cheng Ku, Lalithkumar Seenivasan, Suxi Gu
article en
2 citations

Abstract

Arthroscopy is a minimally invasive surgical procedure used to diagnose and treat joint problems. The clinical workflow of arthroscopy typically involves inserting an arthroscope into the joint through a small incision, during which surgeons navigate and operate largely by relying on their visual assessment through the arthroscope. However, the arthroscope's restricted field of view and lack of depth perception pose challenges in navigating complex articular structures and achieving surgical precision during procedures. Aiming at enhancing intraoperative awareness, a robust pipeline that incorporates simultaneous localization and mapping, depth estimation, and 3D Gaussian splatting (3D GS) is presented to realistically reconstruct intra-articular structures solely based on monocular arthroscope video. Extending 3D reconstruction to augmented reality (AR) applications, the solution offers AR assistance for articular notch measurement and annotation anchoring in a human-in-the-loop manner. Compared to traditional structure-from-motion and neural radiance field-based methods, the pipeline achieves dense 3D reconstruction and competitive rendering fidelity with explicit 3D representation in 7 min on average. When evaluated on four phantom datasets, our method achieves root-mean-square-error <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow><mml:mrow><mml:mtext>(RMSE)</mml:mtext> <mml:mo>=</mml:mo> <mml:mn>2.21</mml:mn> <mml:mspace></mml:mspace> <mml:mtext>mm</mml:mtext></mml:mrow> </mml:mrow> </mml:math> reconstruction error, peak signal-to-noise ratio <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow><mml:mrow><mml:mtext>(PSNR)</mml:mtext> <mml:mo>=</mml:mo> <mml:mn>32.86</mml:mn></mml:mrow> </mml:mrow> </mml:math> and structure similarity index measure <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow><mml:mrow><mml:mtext>(SSIM)</mml:mtext> <mml:mo>=</mml:mo> <mml:mn>0.89</mml:mn></mml:mrow> </mml:mrow> </mml:math> on average. Because the pipeline enables AR reconstruction and guidance directly from monocular arthroscopy without any additional data and/or hardware, the solution may hold the potential for enhancing intraoperative awareness and facilitating surgical precision in arthroscopy. The AR measurement tool achieves accuracy within <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow><mml:mrow><mml:mn>1.59</mml:mn> <mml:mo>±</mml:mo> <mml:mn>1.81</mml:mn> <mml:mspace></mml:mspace> <mml:mtext>mm</mml:mtext></mml:mrow> </mml:mrow> </mml:math> and the AR annotation tool achieves a mIoU of 0.721.

Healthcare Technology LettersVol. 12(1)
Johns Hopkins University (US), Arthrex (United States) (US), Beijing Tsinghua Chang Gung Hospital (CN), Tsinghua University (CN)
Arthrex, Johns Hopkins University
Openalex Percentile: Top 3%
Robotics and Sensor-Based Localization
9.99
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.