Fault Current Limiting Control for AC Side of MMC-HVDC Based on Switched Bang-Bang Control Scheme

Limiting the fault current level of modular multilevel converter (MMC) high-voltage direct current (HVDC) systems is beneficial to reduce the cost of current limiting devices and alleviate the stringent protection time constraints. In this paper, a fault current-limiting strategy based on switched bang-bang control for the AC side of MMC-HVDC system is proposed. The proposed method in this paper is capable of limiting the fault current to an acceptable range within short time. And it not depend on exact system model with a simple control law and small computation. In MMC-HVDC system, the designed switched bang-bang control scheme limits output current of system when it is detected to be overcurrent, and the vector controller is used during normal operation. The performance of the switched bang-bang control strategy is verified by time domain simulation using PSCAD.

Authors

Institutions

Publication Details

Published
2024-09-20
DOI
https://doi.org/10.1109/icpre62586.2024.10768564
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fault Current Limiting Control for AC Side of MMC-HVDC Based on Switched Bang-Bang Control Scheme

Xuelei Feng, Yinsheng Su, Tianhao Wen, Xiaohan Liu et al.
HVDC Systems and Fault Protection
article

Fault Current Limiting Control for AC Side of MMC-HVDC Based on Switched Bang-Bang Control Scheme

Xuelei Feng, Yinsheng Su, Tianhao Wen, Xiaohan Liu, Guanghu Xu, Qin Gao
article en

Abstract

Limiting the fault current level of modular multilevel converter (MMC) high-voltage direct current (HVDC) systems is beneficial to reduce the cost of current limiting devices and alleviate the stringent protection time constraints. In this paper, a fault current-limiting strategy based on switched bang-bang control for the AC side of MMC-HVDC system is proposed. The proposed method in this paper is capable of limiting the fault current to an acceptable range within short time. And it not depend on exact system model with a simple control law and small computation. In MMC-HVDC system, the designed switched bang-bang control scheme limits output current of system when it is detected to be overcurrent, and the vector controller is used during normal operation. The performance of the switched bang-bang control strategy is verified by time domain simulation using PSCAD.

China Southern Power Grid (China) (CN), South China University of Technology (CN)
China Southern Power Grid
Climate action
Openalex Percentile: Top 77%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.