Analysis of A Cable Sheath Voltage Limiter Explosion Accident

This paper analyses an exploding cable sheath Voltage limiter accident and reveals the unstable intermediate state of the it during moisture exposure by simulating water ingress tests of the Voltage limiter as well as insulation resistance and lightning overvoltage tests at various levels of moisture exposure. It was found that deposits or adsorbed layers accumulate on the surface of the valve sheet of the cable sheath Voltage limiter, increasing the resistance of the electrode surface and leading to an increase in resistance. The cause of this explosion accident may have been the failure of the insulation tester used to detect water ingress during the pre-test experiments due to the low conductivity of the hydride of ZnO. As a result, moisture was present inside the protector. When an overcurrent occurs, the liquid water in the moisture rapidly vaporises into water vapour, resulting in a sharp expansion in volume, generating a high pressure that exceeds the withstand capacity of the shell, ultimately leading to a rupture or explosion of the shell.

Authors

Institutions

Publication Details

Published
2024-09-20
DOI
https://doi.org/10.1109/icpre62586.2024.10768435
Citations
1
Primary Topic
Combustion and Detonation Processes
Type
article
Field-Weighted Citation Impact
1.30

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of A Cable Sheath Voltage Limiter Explosion Accident

Hongfa Li, Yanjie Liang, Guoliang Qi, Gang Liu et al.
1 citations
Combustion and Detonation Processes
1.30
article

Analysis of A Cable Sheath Voltage Limiter Explosion Accident

Hongfa Li, Yanjie Liang, Guoliang Qi, Gang Liu, Zhifang Zhang, Feng Gao, Shaobing Cheng, Jiehui Lian
article en
1 citations

Abstract

This paper analyses an exploding cable sheath Voltage limiter accident and reveals the unstable intermediate state of the it during moisture exposure by simulating water ingress tests of the Voltage limiter as well as insulation resistance and lightning overvoltage tests at various levels of moisture exposure. It was found that deposits or adsorbed layers accumulate on the surface of the valve sheet of the cable sheath Voltage limiter, increasing the resistance of the electrode surface and leading to an increase in resistance. The cause of this explosion accident may have been the failure of the insulation tester used to detect water ingress during the pre-test experiments due to the low conductivity of the hydride of ZnO. As a result, moisture was present inside the protector. When an overcurrent occurs, the liquid water in the moisture rapidly vaporises into water vapour, resulting in a sharp expansion in volume, generating a high pressure that exceeds the withstand capacity of the shell, ultimately leading to a rupture or explosion of the shell.

China Southern Power Grid (China) (CN), South China University of Technology (CN)
China Southern Power Grid
Openalex Percentile: Top 11%
Combustion and Detonation Processes
1.30
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of A Cable Sheath Voltage Limiter Explosion Accident — Hongfa Li, Yanjie Liang, et al. · (2024) | TGRS Research Map | TGRS