Operating Conditions for Performance Improvement of Paired Emitter Detector Diode in Optical Measurements Based on Photocapacitance Discharge

The paired emitter detector diode (PEDD) configuration has been applied as an effective option for the implementation of optical measurements systems, since this scheme can be easily implemented in a microcontroller and with a reduced number of components. In this work, an evaluation of the effect on the performance of the measurement system based on photocapacitance discharge of PEDD was performed by modifying the clock frequency of microcontroller, and current supply of emitter LED for light intensity control. These experiments were carried out in turbidity measurement tasks in reference standard samples, and in estimation of biomass concentration in liquid suspensions of the microalgae Spirulina platensis. The results obtained indicates that the sensitivity of the measurement system depends on the light intensity of the LED emitter, as well as the accuracy of the readings is determined by the clock frequency of the microcontroller and suggest that these shall be considered for measurement system based in PEDD configuration.

Authors

Institutions

Publication Details

Published
2024-10-23
DOI
https://doi.org/10.1109/cce62852.2024.10770904
Primary Topic
Water Quality Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Operating Conditions for Performance Improvement of Paired Emitter Detector Diode in Optical Measurements Based on Photocapacitance Discharge

Juan Carlos Rodríguez-Sierra, Mario J. Aguilar‐Méndez, Juan de Dios Ortíz-Alvarado
Water Quality Monitoring and Analysis
article

Operating Conditions for Performance Improvement of Paired Emitter Detector Diode in Optical Measurements Based on Photocapacitance Discharge

Juan Carlos Rodríguez-Sierra, Mario J. Aguilar‐Méndez, Juan de Dios Ortíz-Alvarado
article en

Abstract

The paired emitter detector diode (PEDD) configuration has been applied as an effective option for the implementation of optical measurements systems, since this scheme can be easily implemented in a microcontroller and with a reduced number of components. In this work, an evaluation of the effect on the performance of the measurement system based on photocapacitance discharge of PEDD was performed by modifying the clock frequency of microcontroller, and current supply of emitter LED for light intensity control. These experiments were carried out in turbidity measurement tasks in reference standard samples, and in estimation of biomass concentration in liquid suspensions of the microalgae Spirulina platensis. The results obtained indicates that the sensitivity of the measurement system depends on the light intensity of the LED emitter, as well as the accuracy of the readings is determined by the clock frequency of the microcontroller and suggest that these shall be considered for measurement system based in PEDD configuration.

Instituto Politécnico Nacional (MX)
Affordable and clean energy
Openalex Percentile: Top 68%
Water Quality Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.