Stability Constrained Robust Unit Commitment for LCC-HVDC Transmission Power System with Renewable Energy-Thermal Power Bundled

The transmission of power from large-scale renewable energy-thermal power bundled installations via LCC-HVDC transmission system is considered as a crucial method. To ensure system stability and minimize operational costs, a stability constrained robust unit commitment (UC) model is proposed. First, the model formulates stability constraints, including short-circuit current, voltage stability, and frequency stability. Next, accounting for the N-1 safety criterion, a robust UC model is developed to handle multiple discrete scenarios. Then, a linear equivalent transformation method is devised for the proposed UC model, facilitating the conversion of the original problem into a mixed integer linear programming (MILP) problem. Finally, a modified IEEE 39-bus system is tested to validate the effectiveness of the proposed method.

Authors

Institutions

Publication Details

Published
2024-09-20
DOI
https://doi.org/10.1109/icpre62586.2024.10768373
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stability Constrained Robust Unit Commitment for LCC-HVDC Transmission Power System with Renewable Energy-Thermal Power Bundled

Guoteng Wang, Ying Huang, Keheng Lou
HVDC Systems and Fault Protection
article

Stability Constrained Robust Unit Commitment for LCC-HVDC Transmission Power System with Renewable Energy-Thermal Power Bundled

Guoteng Wang, Ying Huang, Keheng Lou
article en

Abstract

The transmission of power from large-scale renewable energy-thermal power bundled installations via LCC-HVDC transmission system is considered as a crucial method. To ensure system stability and minimize operational costs, a stability constrained robust unit commitment (UC) model is proposed. First, the model formulates stability constraints, including short-circuit current, voltage stability, and frequency stability. Next, accounting for the N-1 safety criterion, a robust UC model is developed to handle multiple discrete scenarios. Then, a linear equivalent transformation method is devised for the proposed UC model, facilitating the conversion of the original problem into a mixed integer linear programming (MILP) problem. Finally, a modified IEEE 39-bus system is tested to validate the effectiveness of the proposed method.

Zhejiang University (CN)
Affordable and clean energy
Openalex Percentile: Top 77%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.