Printed Textile-Based Dry Electrodes for Impedance Plethysmography Measurements

In this work, we report on the design, fabrication, and characterization of dry electrodes for the measurement of pulse plethysmography signals from distal arteries via electrical impedance. Four finger-track electrode designs were fabricated using a screen-printing technique, employing a stretchable Ag paste on a TPU stretchable substrate transferred to a textile structure. Electromechanical measurements (i.e. resistance (Ω) versus elongation (mm)) showed the confirmation of three distinct stages: stretchability, relaxation, and swelling on the printed tracks, where the finger tracks #1, #2, and #4 demonstrated a stable return to zero resistance and track #3 exhibited a negative return-to-zero value, with a decrease of a normalized resistance of 0.5 Ω. Furthermore, a preliminary test with the electrodes, demonstrates plethysmography signal waveforms are comparable to typical waveforms obtained with disposable gel electrodes.

Authors

Institutions

Publication Details

Published
2024-09-15
DOI
https://doi.org/10.1109/ifetc61155.2024.10771867
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Printed Textile-Based Dry Electrodes for Impedance Plethysmography Measurements

Albert Heinrich Lanthaler, Niko Münzenrieder, Giuseppe Cantarella, Luisa Petti et al.
Advanced Sensor and Energy Harvesting Materials
article

Printed Textile-Based Dry Electrodes for Impedance Plethysmography Measurements

Albert Heinrich Lanthaler, Niko Münzenrieder, Giuseppe Cantarella, Luisa Petti, Antonio Altana, Christian Tronstad, Martina Aurora Costa Angeli, Paolo Lugli, Pietro Ibba, Camilo Eduardo Téllez Villamizar
article en

Abstract

In this work, we report on the design, fabrication, and characterization of dry electrodes for the measurement of pulse plethysmography signals from distal arteries via electrical impedance. Four finger-track electrode designs were fabricated using a screen-printing technique, employing a stretchable Ag paste on a TPU stretchable substrate transferred to a textile structure. Electromechanical measurements (i.e. resistance (Ω) versus elongation (mm)) showed the confirmation of three distinct stages: stretchability, relaxation, and swelling on the printed tracks, where the finger tracks #1, #2, and #4 demonstrated a stable return to zero resistance and track #3 exhibited a negative return-to-zero value, with a decrease of a normalized resistance of 0.5 Ω. Furthermore, a preliminary test with the electrodes, demonstrates plethysmography signal waveforms are comparable to typical waveforms obtained with disposable gel electrodes.

University of Modena and Reggio Emilia (IT), Oslo University Hospital (NO), Free University of Bozen-Bolzano (IT)
Openalex Percentile: Top 77%
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.