Simulation of Fluid-Thermal Field of Oil-immersed Transformer and Analysis of Local Overheating of Winding

In this paper, based on the coupling calculation method of flow field-temperature field of oil-immersed transformer, in order to take into account the calculation efficiency and accuracy of multiple physical fields, a simulation model of low-voltage winding is established according to the electrical and structural parameters of oil-immersed transformer, and the simulation results of flow field and temperature field of low-voltage winding are obtained. On this basis, the influence of different overheating positions of the winding on local regional temperature of the winding is analyzed according to the simulation results of the temperature field. It is obtained that when overheating occurs at different positions of the winding, the heat in the overheating area will be transferred by the oil flow to the upper part, so that the temperature of each point in the winding oil passage increases linearly with the increase of the overheating temperature in the lower part. The accuracy of this method is 98%, which has important guiding significance for determining the overheat position of oil-immersed transformer and prolonging the service life of transformer.

Authors

Publication Details

Published
2024-09-20
DOI
https://doi.org/10.1109/icpre62586.2024.10768644
Citations
1
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation of Fluid-Thermal Field of Oil-immersed Transformer and Analysis of Local Overheating of Winding

Guohua Luo, Lei Wang, Zequn Yang, Yong Dai
1 citations
Power Transformer Diagnostics and Insulation
0.21
article

Simulation of Fluid-Thermal Field of Oil-immersed Transformer and Analysis of Local Overheating of Winding

Guohua Luo, Lei Wang, Zequn Yang, Yong Dai
article en
1 citations

Abstract

In this paper, based on the coupling calculation method of flow field-temperature field of oil-immersed transformer, in order to take into account the calculation efficiency and accuracy of multiple physical fields, a simulation model of low-voltage winding is established according to the electrical and structural parameters of oil-immersed transformer, and the simulation results of flow field and temperature field of low-voltage winding are obtained. On this basis, the influence of different overheating positions of the winding on local regional temperature of the winding is analyzed according to the simulation results of the temperature field. It is obtained that when overheating occurs at different positions of the winding, the heat in the overheating area will be transferred by the oil flow to the upper part, so that the temperature of each point in the winding oil passage increases linearly with the increase of the overheating temperature in the lower part. The accuracy of this method is 98%, which has important guiding significance for determining the overheat position of oil-immersed transformer and prolonging the service life of transformer.

Openalex Percentile: Top 44%
Power Transformer Diagnostics and Insulation
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Simulation of Fluid-Thermal Field of Oil-immersed Transformer and Analysis of Local Overheating of Winding — Guohua Luo, Lei Wang, et al. · (2024) | TGRS Research Map | TGRS