Modified CA-CFAR Detector for Oversampled Sensors

To ensure less quantization error and sampling loss, oversampling is very common in radar, sonar, communications and other applications. The cell averaging constant false alarm rate (CA-CFAR) is widely used in target detection due to its ability to adaptively adjust the detection threshold based on varying background noise levels and maintain a constant false alarm rate. However, a high oversampling ratio (OSR) will increase the correlation degree of the sample data, which will distort the maximum likelihood estimation (MLE) of the background noise power obtained by the traditional CA-CFAR detector and consequently weaken its detection performance. To solve this problem, a modified CA-CFAR detector is proposed in this paper. Utilizing the colored filter matrix, the MLE of the covariance matrix of the data in the reference window is obtained, based on which the modified test statistics are derived via the generalized likelihood ratio test. The simulation results show that the modified CA-CFAR detector can achieve the upper performance bound for different OSRs.

Authors

Institutions

Publication Details

Published
2024-08-19
DOI
https://doi.org/10.1109/icspcc62635.2024.10770434
Citations
1
Primary Topic
CCD and CMOS Imaging Sensors
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modified CA-CFAR Detector for Oversampled Sensors

Qingfu Zhang, Chang Gao, Hongwei Liu, Rongrong Wang et al.
1 citations
CCD and CMOS Imaging Sensors
0.21
article

Modified CA-CFAR Detector for Oversampled Sensors

Qingfu Zhang, Chang Gao, Hongwei Liu, Rongrong Wang, Fengdeng Gu
article en
1 citations

Abstract

To ensure less quantization error and sampling loss, oversampling is very common in radar, sonar, communications and other applications. The cell averaging constant false alarm rate (CA-CFAR) is widely used in target detection due to its ability to adaptively adjust the detection threshold based on varying background noise levels and maintain a constant false alarm rate. However, a high oversampling ratio (OSR) will increase the correlation degree of the sample data, which will distort the maximum likelihood estimation (MLE) of the background noise power obtained by the traditional CA-CFAR detector and consequently weaken its detection performance. To solve this problem, a modified CA-CFAR detector is proposed in this paper. Utilizing the colored filter matrix, the MLE of the covariance matrix of the data in the reference window is obtained, based on which the modified test statistics are derived via the generalized likelihood ratio test. The simulation results show that the modified CA-CFAR detector can achieve the upper performance bound for different OSRs.

Xidian University (CN), City University of Hong Kong (HK)
Affordable and clean energy
Openalex Percentile: Top 44%
CCD and CMOS Imaging Sensors
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Modified CA-CFAR Detector for Oversampled Sensors — Qingfu Zhang, Chang Gao, et al. · (2024) | TGRS Research Map | TGRS