Thyroidiomics: An Automated Pipeline for Segmentation and Classification of Thyroid Pathologies from Scintigraphy Images

The objective of this study was to develop an automated pipeline that enhances thyroid disease classification using thyroid scintigraphy images, aiming to decrease assessment time and increase diagnostic accuracy. Anterior thyroid scintigraphy images from 2,643 patients were collected and categorized into diffuse goiter (DG), multinodal goiter (MNG), and thyroiditis (TH) based on clinical reports, and then segmented by an expert. A Residual UNet (ResUNet) model was trained to perform auto-segmentation. Radiomic features were extracted from both physician (scenario 1) and ResUNet segmentations (scenario 2), followed by omitting highly correlated features using Spearman's correlation, and feature selection using Recursive Feature Elimination (RFE) with eXtreme Gradient Boosting (XGBoost) as the core. All models were trained under a leave-one-center-out cross-validation (LOCOCV) scheme. Segmentation performance was assessed using the Dice similarity coefficient (DSC), while classification performance was assessed using metrics, such as precision, recall, F1-score, accuracy, area under the Receiver Operating Characteristic (ROC AUC), and area under the precision-recall curve (PRC AUC). ResUNet achieved DSC values of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$0.84\pm 0.03,0.71\pm 0.06$</tex>, and <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$0.86\pm 0.02$</tex> for MNG, TH, and DG, respectively. Classification in scenario 1 achieved an accuracy of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$0.76\pm 0.04$</tex> and a ROC AUC of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$0.92\pm 0.02$</tex> while in scenario 2, classification yielded an accuracy of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$0.74\pm 0.05$</tex> and a ROC AUC of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$0.90\pm 0.02$</tex>. The automated pipeline demonstrated comparable performance to physician segmentations on several classification metrics across different classes, effectively reducing assessment time while maintaining high diagnostic accuracy. The code is available at: https://github.com/ahxmeds/thyroidiomics.git.

Authors

Institutions

Publication Details

Published
2024-09-08
DOI
https://doi.org/10.1109/euvip61797.2024.10772785
Citations
3
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
1.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thyroidiomics: An Automated Pipeline for Segmentation and Classification of Thyroid Pathologies from Scintigraphy Images

Atlas Haddadi Avval, Habib Zaidi, Arman Rahmim, Ali Rasouli et al.
3 citations
Radiomics and Machine Learning in Medical Imaging
1.21
article

Thyroidiomics: An Automated Pipeline for Segmentation and Classification of Thyroid Pathologies from Scintigraphy Images

Atlas Haddadi Avval, Habib Zaidi, Arman Rahmim, Ali Rasouli, Seyed Rasoul Zakavi, Emran Askari, Shadab Ahamed, Ghasem Hajianfar, Fereshteh Yousefirizi, Mohsen Arabi, Carlos Uribe, Atena Aghaee, Soroush Bagheri, Maziar Sabouri, Mohaddese Sehati, Azin Asadzadeh
article en
3 citations

Abstract

The objective of this study was to develop an automated pipeline that enhances thyroid disease classification using thyroid scintigraphy images, aiming to decrease assessment time and increase diagnostic accuracy. Anterior thyroid scintigraphy images from 2,643 patients were collected and categorized into diffuse goiter (DG), multinodal goiter (MNG), and thyroiditis (TH) based on clinical reports, and then segmented by an expert. A Residual UNet (ResUNet) model was trained to perform auto-segmentation. Radiomic features were extracted from both physician (scenario 1) and ResUNet segmentations (scenario 2), followed by omitting highly correlated features using Spearman's correlation, and feature selection using Recursive Feature Elimination (RFE) with eXtreme Gradient Boosting (XGBoost) as the core. All models were trained under a leave-one-center-out cross-validation (LOCOCV) scheme. Segmentation performance was assessed using the Dice similarity coefficient (DSC), while classification performance was assessed using metrics, such as precision, recall, F1-score, accuracy, area under the Receiver Operating Characteristic (ROC AUC), and area under the precision-recall curve (PRC AUC). ResUNet achieved DSC values of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$0.84\pm 0.03,0.71\pm 0.06$</tex>, and <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$0.86\pm 0.02$</tex> for MNG, TH, and DG, respectively. Classification in scenario 1 achieved an accuracy of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$0.76\pm 0.04$</tex> and a ROC AUC of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$0.92\pm 0.02$</tex> while in scenario 2, classification yielded an accuracy of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$0.74\pm 0.05$</tex> and a ROC AUC of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$0.90\pm 0.02$</tex>. The automated pipeline demonstrated comparable performance to physician segmentations on several classification metrics across different classes, effectively reducing assessment time while maintaining high diagnostic accuracy. The code is available at: https://github.com/ahxmeds/thyroidiomics.git.

University of British Columbia (CA), Mashhad University of Medical Sciences (IR), Golestan University (IR), Kashan University of Medical Sciences (IR), University Hospital of Geneva (CH), Jahrom University of Medical Sciences (IR), Golestan University of Medical Sciences (IR), Alborz University of Medical Sciences (IR)
BC Cancer Foundation, Natural Sciences and Engineering Research Council of Canada
Openalex Percentile: Top 19%
Radiomics and Machine Learning in Medical Imaging
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.