Commercial-Off-the-Shelf (COTS) Wearable Elbow Joint Angle Measurement System

Measuring joint angles is crucial for kinematic analysis of human movement. The measurement of range of motion (ROM) is particularly essential for evaluation of a patient's joint function in physical therapy and rehabilitation. Physical therapists and physicians typically use a mechanical goniometer to measure joint angles in clinical settings. However, this measurement is often limited by low accuracy, limited resolution, and observation error. This study presents a commercial-off-the-shelf (COTS) wearable elbow joint angle measurement system, which would enhance the measurement accuracy. The accuracy of the system was evaluated in two test setups: 1) desktop test setup without human subjects and 2) wearable test setup with human subjects. In the test without human subjects, the angle measurement was repeated for five times at the angles varied from 60° to 180° by 10° increments. In the test with human subjects, nine healthy human subjects participated in the experiment. Three representative elbow joint angles between 60° and 180° were measured for 10 times at each subject (60°, 120°, and 180°). The average error of the measured angle was 0.52±0.34 % (AVR±STE) at the desktop test without human subjects. The average error of the measured angle at the test with nine human subjects was -0.29±0.10%. These results indicate that the presented system can measure the elbow joint angle in high accuracy and consistency.

Authors

Institutions

Publication Details

Published
2024-11-03
DOI
https://doi.org/10.1109/icce-asia63397.2024.10773881
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Commercial-Off-the-Shelf (COTS) Wearable Elbow Joint Angle Measurement System

Deog Young Kim, Youngdeok Kim, Jong Weon Lee, Hangue Park et al.
Muscle activation and electromyography studies
article

Commercial-Off-the-Shelf (COTS) Wearable Elbow Joint Angle Measurement System

Deog Young Kim, Youngdeok Kim, Jong Weon Lee, Hangue Park, Sanghoon Han
article en

Abstract

Measuring joint angles is crucial for kinematic analysis of human movement. The measurement of range of motion (ROM) is particularly essential for evaluation of a patient's joint function in physical therapy and rehabilitation. Physical therapists and physicians typically use a mechanical goniometer to measure joint angles in clinical settings. However, this measurement is often limited by low accuracy, limited resolution, and observation error. This study presents a commercial-off-the-shelf (COTS) wearable elbow joint angle measurement system, which would enhance the measurement accuracy. The accuracy of the system was evaluated in two test setups: 1) desktop test setup without human subjects and 2) wearable test setup with human subjects. In the test without human subjects, the angle measurement was repeated for five times at the angles varied from 60° to 180° by 10° increments. In the test with human subjects, nine healthy human subjects participated in the experiment. Three representative elbow joint angles between 60° and 180° were measured for 10 times at each subject (60°, 120°, and 180°). The average error of the measured angle was 0.52±0.34 % (AVR±STE) at the desktop test without human subjects. The average error of the measured angle at the test with nine human subjects was -0.29±0.10%. These results indicate that the presented system can measure the elbow joint angle in high accuracy and consistency.

Yonsei University (KR), Sungkyunkwan University (KR)
National Research Foundation of Korea
Openalex Percentile: Top 77%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Commercial-Off-the-Shelf (COTS) Wearable Elbow Joint Angle Measurement System — Deog Young Kim, Youngdeok Kim, et al. · (2024) | TGRS Research Map | TGRS