Optimization Configuration Method of Energy Storage Considering Photovoltaic Power Consumption and Source-Load Uncertainty

The proposal of a "double carbon" target has resulted in a gradual continuous increase in the proportion of photovoltaic (PV) access to the distribution network area. To enhance the capability of PV consumption and mitigate the voltage overrun issue stemming from the substantial PV access proportion, this paper puts forth a multi-objective energy storage optimization allocation methodology. Firstly, a PV and load uncertainty model is established based on Beta and Normal distributions, and the Monte Carlo Method (MC) is used to simulate the annual output. The representative scenarios are obtained after the combination is cut down by the K-means clustering algorithm. The bad operation scenarios are identified by using the variation of the maximum total node voltage deviation. Finally, an energy storage optimization allocation is proposed. Subsequently, the objective function, which seeks to minimize the total daily operating cost of the energy storage system and the PV abandonment rate, is constructed using the evaluation function method. The constraints, including node voltage and energy storage device, are considered, and the model is solved using the improved grey wolf optimization algorithm. Finally, a distribution network station system is employed to compare and analyze the capacity allocation results of poor operation scenarios under different schemes, the results showed that after energy storage optimization, the voltage of each scheme decreased from 0.4869kV to 0.42kV, and the curtailment rate decreased by 13.09%, 21.33%, and 23.69% respectively compared to before optimization,which verifys the effectiveness of the models and methods proposed in this paper.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3528050
Citations
12
Primary Topic
Solar Radiation and Photovoltaics
Type
article
Field-Weighted Citation Impact
29.77
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization Configuration Method of Energy Storage Considering Photovoltaic Power Consumption and Source-Load Uncertainty

Y. P. Xu, Weigang Zheng, Ping Huang, Qiao Junjie et al.
12 citations
IEEE Access
Solar Radiation and Photovoltaics
29.77
article

Optimization Configuration Method of Energy Storage Considering Photovoltaic Power Consumption and Source-Load Uncertainty

Y. P. Xu, Weigang Zheng, Ping Huang, Qiao Junjie, Xiaofang Meng, Tiefeng Xuu
article en
12 citations

Abstract

The proposal of a "double carbon" target has resulted in a gradual continuous increase in the proportion of photovoltaic (PV) access to the distribution network area. To enhance the capability of PV consumption and mitigate the voltage overrun issue stemming from the substantial PV access proportion, this paper puts forth a multi-objective energy storage optimization allocation methodology. Firstly, a PV and load uncertainty model is established based on Beta and Normal distributions, and the Monte Carlo Method (MC) is used to simulate the annual output. The representative scenarios are obtained after the combination is cut down by the K-means clustering algorithm. The bad operation scenarios are identified by using the variation of the maximum total node voltage deviation. Finally, an energy storage optimization allocation is proposed. Subsequently, the objective function, which seeks to minimize the total daily operating cost of the energy storage system and the PV abandonment rate, is constructed using the evaluation function method. The constraints, including node voltage and energy storage device, are considered, and the model is solved using the improved grey wolf optimization algorithm. Finally, a distribution network station system is employed to compare and analyze the capacity allocation results of poor operation scenarios under different schemes, the results showed that after energy storage optimization, the voltage of each scheme decreased from 0.4869kV to 0.42kV, and the curtailment rate decreased by 13.09%, 21.33%, and 23.69% respectively compared to before optimization,which verifys the effectiveness of the models and methods proposed in this paper.

IEEE AccessVol. 13
Electric Power Research Institute (US), Shenyang Agricultural University (CN), State Grid Corporation of China (China) (CN), Shanghai Electric (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 1%
Solar Radiation and Photovoltaics
29.77
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.