Improvement of Power Quality in Distribution Network at low voltage side by using DVR

The study investigated a power distribution system design featuring two feeder lines and a coupling bus tied to a single power supply. One of the feeder lines (Feeder Line 2) includes a Dynamic Voltage Restorer (DVR) can inject the missing energy to a nonlinear load, Feeder Line 1, on the other hand, supplies power to a resistive load. The primary objective is to assess the impact of the DVR on both feeder lines under various disturbances like frequency deviations, voltage transients, voltage instability, and flickers. Key findings highlight “a Potential of the Dynamic Voltage Restorer (DVR) to alleviate power quality issues, improving the load profile across the system. Additionally, a overall harmonic distortion or Total Harmonic Distortion (THD) values remained below a $5 \%$ threshold in all cases, except for voltage instability and flickers. This study emphasizes the role of customized power devices, such as DVRs, in improving power quality, especially in complex systems prone to disturbances.

Authors

Institutions

Publication Details

Published
2024-09-12
DOI
https://doi.org/10.1109/sparc61891.2024.10828650
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improvement of Power Quality in Distribution Network at low voltage side by using DVR

Anurag Verma, Raj Kumar Chaudhari
Power Quality and Harmonics
article

Improvement of Power Quality in Distribution Network at low voltage side by using DVR

Anurag Verma, Raj Kumar Chaudhari
article en

Abstract

The study investigated a power distribution system design featuring two feeder lines and a coupling bus tied to a single power supply. One of the feeder lines (Feeder Line 2) includes a Dynamic Voltage Restorer (DVR) can inject the missing energy to a nonlinear load, Feeder Line 1, on the other hand, supplies power to a resistive load. The primary objective is to assess the impact of the DVR on both feeder lines under various disturbances like frequency deviations, voltage transients, voltage instability, and flickers. Key findings highlight “a Potential of the Dynamic Voltage Restorer (DVR) to alleviate power quality issues, improving the load profile across the system. Additionally, a overall harmonic distortion or Total Harmonic Distortion (THD) values remained below a $5 \%$ threshold in all cases, except for voltage instability and flickers. This study emphasizes the role of customized power devices, such as DVRs, in improving power quality, especially in complex systems prone to disturbances.

Indian Institute of Management Lucknow (IN)
Affordable and clean energy
Openalex Percentile: Top 77%
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.