Electrochemical Sensor With Dynamic Self-Calibration for Acetaminophen Detection in Water

This letter introduces a self-calibrating electrochemical sensor for water acetaminophen detection. The sensor is built upon a graphite pencil lead electrode modified with a molecularly imprinted polymer to ensure selectivity. Moreover, using a sparse identification scheme, the sensor is equipped with a dynamic calibration algorithm to increase the sensor accuracy in time-dependent measurements. The sensor performance was evaluated under static and dynamic conditions using ACT solutions prepared in tap water as the matrix. As a result, the sensor achieved a detection limit of 9.3 mg/L, proving to be a viable alternative for quantifying emerging concerns in water. Finally, we show how simple but robust sensor models could enhance the performance of online measurements

Authors

Publication Details

Journal
IEEE Sensors Letters
Published
2025-01-10
DOI
https://doi.org/10.1109/lsens.2025.3528342
Citations
2
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
1.47
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical Sensor With Dynamic Self-Calibration for Acetaminophen Detection in Water

Bryan E. Alvarez-Serna, Jorge A. Uc-Martín, Daniel A. Arcos-Santiago, Roberto G. Ram ́rez-Chavarría
2 citations
IEEE Sensors Letters
Analytical Chemistry and Sensors
1.47
article

Electrochemical Sensor With Dynamic Self-Calibration for Acetaminophen Detection in Water

Bryan E. Alvarez-Serna, Jorge A. Uc-Martín, Daniel A. Arcos-Santiago, Roberto G. Ram ́rez-Chavarría
article en
2 citations

Abstract

This letter introduces a self-calibrating electrochemical sensor for water acetaminophen detection. The sensor is built upon a graphite pencil lead electrode modified with a molecularly imprinted polymer to ensure selectivity. Moreover, using a sparse identification scheme, the sensor is equipped with a dynamic calibration algorithm to increase the sensor accuracy in time-dependent measurements. The sensor performance was evaluated under static and dynamic conditions using ACT solutions prepared in tap water as the matrix. As a result, the sensor achieved a detection limit of 9.3 mg/L, proving to be a viable alternative for quantifying emerging concerns in water. Finally, we show how simple but robust sensor models could enhance the performance of online measurements

IEEE Sensors LettersVol. 9(2)
Clean water and sanitation
Openalex Percentile: Top 24%
Analytical Chemistry and Sensors
1.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.