An 80 MS/s 70.8 dB-SNDR Radiation-Tolerant Semi-Time-Interleaved Pipelined-SAR ADC for Space Applications

In addition to the conventional ADC design tradeoffs between power, speed, and accuracy, radiation tolerance is the fourth factor for ADCs used in radiation environments. This paper describes radiation-tolerant (RT) ADC design tradeoffs and design strategies. Then, the paper introduces a 13-bit RT pipelined-successive-approximation register (pipelined-SAR) ADC fabricated in 65 nm CMOS technology based on the concluded tradeoffs. To further improve the ADC power efficiency, a semi-time-interleaved (Semi-TI) structure is employed. Besides, the ping-pong auto-zeroing (AZ) scheme is implemented in the residue amplifier (RA) to reduce the TID-induced offset while maintaining low power dissipation. The proposed ADC is designed and hardened against Single Event Effects (SEEs) and Total Ionizing Dose (TID) effects from the structure to layout levels. All sub-blocks were examined, and only the critical blocks were hardened to avoid over-hardening. From the measurement results, the prototype ADC attains an 80 MS/s sampling rate and achieves 70.8-dB SNDR and 80.3-dB SFDR at the Nyquist input frequency. With a total power consumption of 13.8 mW, the prototype ADC establishes a state-of-the-art Walden Figure of Merit of 60.7 fJ/conv step, yielding an efficiency comparable to non-RT ADCs with similar specifications. Irradiation tests validate the consistent performance of the ADC up to a cumulative dose of 500 krad (Si) in X-ray testing, while laser testing indicates a robust SEE threshold and swift post-SEE recovery.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Circuits and Systems I Regular Papers
Published
2025-01-10
DOI
https://doi.org/10.1109/tcsi.2024.3516475
Citations
2
Primary Topic
Radiation Effects in Electronics
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An 80 MS/s 70.8 dB-SNDR Radiation-Tolerant Semi-Time-Interleaved Pipelined-SAR ADC for Space Applications

Zheyi Li, Laurent Berti, Paul Leroux, Qiuyang Lin et al.
2 citations
IEEE Transactions on Circuits and Systems I Regular Papers
Radiation Effects in Electronics
1.46
article

An 80 MS/s 70.8 dB-SNDR Radiation-Tolerant Semi-Time-Interleaved Pipelined-SAR ADC for Space Applications

Zheyi Li, Laurent Berti, Paul Leroux, Qiuyang Lin, Geert Thys, Jinghao Zhao, Maxim S. Gorbunov, Shiwei Wang
article en
2 citations

Abstract

In addition to the conventional ADC design tradeoffs between power, speed, and accuracy, radiation tolerance is the fourth factor for ADCs used in radiation environments. This paper describes radiation-tolerant (RT) ADC design tradeoffs and design strategies. Then, the paper introduces a 13-bit RT pipelined-successive-approximation register (pipelined-SAR) ADC fabricated in 65 nm CMOS technology based on the concluded tradeoffs. To further improve the ADC power efficiency, a semi-time-interleaved (Semi-TI) structure is employed. Besides, the ping-pong auto-zeroing (AZ) scheme is implemented in the residue amplifier (RA) to reduce the TID-induced offset while maintaining low power dissipation. The proposed ADC is designed and hardened against Single Event Effects (SEEs) and Total Ionizing Dose (TID) effects from the structure to layout levels. All sub-blocks were examined, and only the critical blocks were hardened to avoid over-hardening. From the measurement results, the prototype ADC attains an 80 MS/s sampling rate and achieves 70.8-dB SNDR and 80.3-dB SFDR at the Nyquist input frequency. With a total power consumption of 13.8 mW, the prototype ADC establishes a state-of-the-art Walden Figure of Merit of 60.7 fJ/conv step, yielding an efficiency comparable to non-RT ADCs with similar specifications. Irradiation tests validate the consistent performance of the ADC up to a cumulative dose of 500 krad (Si) in X-ray testing, while laser testing indicates a robust SEE threshold and swift post-SEE recovery.

IEEE Transactions on Circuits and Systems I Regular PapersVol. 72(8)
IMEC (BE), University of Edinburgh (GB), KU Leuven (BE)
Affordable and clean energy
Openalex Percentile: Top 20%
Radiation Effects in Electronics
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.