Correction of non-uniform rotational distortion in proximally controlled endoscopic OCT using microfluidic phantom

In endoscopic OCT systems, the imbalance in torque load during rotational scanning will lead to non-uniform rotation of the distal probe, inevitably resulting in Non-Uniform Rotational Distortion (NURD) in the images. NURD can cause image translation and stretching or compression issues at arbitrary positions in OCT images, leading to misalignment of image information and impeding the implementation of endoscopic OCTA. In high-speed distal scanning OCT system, the instantaneous rotational speed of the micro-motor's metal struts was measured for OCT data resampling, enabling NURD correction, and OCTA was successfully realized. In proximal scanning, NURD is a more serious problem due to torque transmission over longer distances, resulting in asymmetric friction at different positions. In recent years, local block matching (LBM) and improved Features from Accelerated Segment Test (FAST) algorithms were used to solve NURD in B-scan images in proximal controlling OCT system. Cross-sectional OCTA was successfully implemented. In this paper, Global registration and A-line registration were used to correct NURD in continuous rotation and retraction of proximally controlled OCT imaging. Global registration was used to correct extensive NURD in B-scan images and A-line registration was applied for fine correction of minor NURD. Results from microfluidic data collected under the same position and retraction conditions demonstrate the effectiveness of NURD correction, and en face OCTA imaging was realized for the first time in a proximally controlled endoscopic OCT.

Authors

Institutions

Publication Details

Published
2025-01-10
DOI
https://doi.org/10.1117/12.3056817
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correction of non-uniform rotational distortion in proximally controlled endoscopic OCT using microfluidic phantom

Cuixia Dai, Guangsen Jia, Wenjuan Wu, Shuhao Fan et al.
1 links
Coronary Interventions and Diagnostics
article

Correction of non-uniform rotational distortion in proximally controlled endoscopic OCT using microfluidic phantom

Cuixia Dai, Guangsen Jia, Wenjuan Wu, Shuhao Fan, Xu Feng, Zehua Guan
article en

Abstract

In endoscopic OCT systems, the imbalance in torque load during rotational scanning will lead to non-uniform rotation of the distal probe, inevitably resulting in Non-Uniform Rotational Distortion (NURD) in the images. NURD can cause image translation and stretching or compression issues at arbitrary positions in OCT images, leading to misalignment of image information and impeding the implementation of endoscopic OCTA. In high-speed distal scanning OCT system, the instantaneous rotational speed of the micro-motor's metal struts was measured for OCT data resampling, enabling NURD correction, and OCTA was successfully realized. In proximal scanning, NURD is a more serious problem due to torque transmission over longer distances, resulting in asymmetric friction at different positions. In recent years, local block matching (LBM) and improved Features from Accelerated Segment Test (FAST) algorithms were used to solve NURD in B-scan images in proximal controlling OCT system. Cross-sectional OCTA was successfully implemented. In this paper, Global registration and A-line registration were used to correct NURD in continuous rotation and retraction of proximally controlled OCT imaging. Global registration was used to correct extensive NURD in B-scan images and A-line registration was applied for fine correction of minor NURD. Results from microfluidic data collected under the same position and retraction conditions demonstrate the effectiveness of NURD correction, and en face OCTA imaging was realized for the first time in a proximally controlled endoscopic OCT.

Shanghai Jiao Tong University (CN), XinHua Hospital (CN), Shanghai Institute of Technology (CN)
Openalex Percentile: Top 99%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.