Lateral flow immunoassay combined with color saturation for smartphone-based quantitative point-of-care detection of <i>Klebsiella pneumoniae</i>

Abstract Klebsiella pneumoniae is one of the most common pathogenic, multidrug-resistant Gram-negative bacteria that triggers postoperative infections, leading to septic shock and fatality. Therefore, there is an urgent need to generate rapid and sensitive diagnosis techniques for timely and effective intervention. The present work described the fabrication of lateral flow immunoassays (LFIA) based on antibody-gold nanoparticle covalent conjugation combined with an RGB system to detect Klebsiella pneumoniae quantitatively. The LFIAs showed the lines after 15 min with good sensitivity and a low limit of detection of 2.40 CFUs ml −1 in the linear detection range of this immunosensor from 10 1 to 10 8 CFUs ml −1 when combined with the color saturation system. No false positives and cross-reactions were observed on the test strips in this study, indicating that the system was optimized with high specificity. This finding might provide a well-suited solution for a quick, inexpensive, and easy-to-use detection method for potential commercial manufacture.

Authors

Institutions

Publication Details

Journal
Advances in Natural Sciences Nanoscience and Nanotechnology
Published
2025-01-10
DOI
https://doi.org/10.1088/2043-6262/ada006
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lateral flow immunoassay combined with color saturation for smartphone-based quantitative point-of-care detection of Klebsiella pneumoniae

Tam Nguyen Truong, Тран Дай Лам, Nguyễn Thị Thanh Huyền, Thu Thao Pham
Advances in Natural Sciences Nanoscience and Nanotechnology
Biosensors and Analytical Detection
article

Lateral flow immunoassay combined with color saturation for smartphone-based quantitative point-of-care detection of Klebsiella pneumoniae

Tam Nguyen Truong, Тран Дай Лам, Nguyễn Thị Thanh Huyền, Thu Thao Pham
article en

Abstract

Abstract Klebsiella pneumoniae is one of the most common pathogenic, multidrug-resistant Gram-negative bacteria that triggers postoperative infections, leading to septic shock and fatality. Therefore, there is an urgent need to generate rapid and sensitive diagnosis techniques for timely and effective intervention. The present work described the fabrication of lateral flow immunoassays (LFIA) based on antibody-gold nanoparticle covalent conjugation combined with an RGB system to detect Klebsiella pneumoniae quantitatively. The LFIAs showed the lines after 15 min with good sensitivity and a low limit of detection of 2.40 CFUs ml −1 in the linear detection range of this immunosensor from 10 1 to 10 8 CFUs ml −1 when combined with the color saturation system. No false positives and cross-reactions were observed on the test strips in this study, indicating that the system was optimized with high specificity. This finding might provide a well-suited solution for a quick, inexpensive, and easy-to-use detection method for potential commercial manufacture.

Advances in Natural Sciences Nanoscience and NanotechnologyVol. 16(1)
Vietnam Academy of Science and Technology (VN), Hanoi University of Science and Technology (VN)
Good health and well-being
Openalex Percentile: Top 100%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.