Feasibility study on dose conversion using a deep learning algorithm for retrospective dosimetry

The application of deep learning-based artificial intelligence (AI) models for dose estimation has garnered significant attention in dosimetric research, aiming to supplement or replace Monte Carlo (MC) particle transport simulations. The present study explores the feasibility of AI-based dose conversion techniques for retrospective dosimetry in radiological emergencies, particularly focusing on scenarios where a rapid estimation of body dose is required using measured doses from fortuitous dosimeters placed on or near the body during exposure. With the modeling of an International Commission on Radiation Units and Measurements (ICRU) slab phantom (presuming a human body) and glass plates (presuming fortuitous dosimeters), a large amount of dose data was generated through MC simulations with respect to randomly generated point sources ( 192 Ir, 137 Cs, and 60 Co) within a radius of 3 m from the phantom center. A deep learning (DL) model was trained to estimate doses and dose conversion coefficients (DCCs) between the phantom and the glass plates using the input of exposure structures, i.e. the position and energy of the source. Data scaling, such as logarithmic or power transformations, was essential for the dose data due to its highly biased distribution. The results showed that 98% of the estimated doses had relative differences (RDs) within ±3% when compared to MC simulations. To assess the impact of data volume on performance, datasets of varying sizes (55 k, 108 k, 216 k, and 432 k) were used for training, revealing a strong dependence of model performance on data volume. Outlier reduction methods, such as dose averaging and data reduction near the center, were applied, reducing the max-min RD range by a factor of 3 to 10. From the results, the potential and necessity of an AI dose estimation model for more complicated geometries, such as those involving anthropomorphic phantoms, were discussed. • The feasibility of a deep-learning model for dose conversion in retrospective dosimetry was investigated. • A slab phantom and glass plates, assumed to represent a human body and fortuitous dosimeters, respectively, were used. • Dose conversion coefficients from the Monte Carlo simulation were compared with those from the deep-learning model.

Authors

Institutions

Publication Details

Journal
Radiation Measurements
Published
2025-01-10
DOI
https://doi.org/10.1016/j.radmeas.2025.107382
Citations
2
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
3.77

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility study on dose conversion using a deep learning algorithm for retrospective dosimetry

Byoungil Jeon, Min Chae Kim, Yoomi Choi, Hyoungtaek Kim
2 citations
Radiation Measurements
Advanced Radiotherapy Techniques
3.77
article

Feasibility study on dose conversion using a deep learning algorithm for retrospective dosimetry

Byoungil Jeon, Min Chae Kim, Yoomi Choi, Hyoungtaek Kim
article en
2 citations

Abstract

The application of deep learning-based artificial intelligence (AI) models for dose estimation has garnered significant attention in dosimetric research, aiming to supplement or replace Monte Carlo (MC) particle transport simulations. The present study explores the feasibility of AI-based dose conversion techniques for retrospective dosimetry in radiological emergencies, particularly focusing on scenarios where a rapid estimation of body dose is required using measured doses from fortuitous dosimeters placed on or near the body during exposure. With the modeling of an International Commission on Radiation Units and Measurements (ICRU) slab phantom (presuming a human body) and glass plates (presuming fortuitous dosimeters), a large amount of dose data was generated through MC simulations with respect to randomly generated point sources ( 192 Ir, 137 Cs, and 60 Co) within a radius of 3 m from the phantom center. A deep learning (DL) model was trained to estimate doses and dose conversion coefficients (DCCs) between the phantom and the glass plates using the input of exposure structures, i.e. the position and energy of the source. Data scaling, such as logarithmic or power transformations, was essential for the dose data due to its highly biased distribution. The results showed that 98% of the estimated doses had relative differences (RDs) within ±3% when compared to MC simulations. To assess the impact of data volume on performance, datasets of varying sizes (55 k, 108 k, 216 k, and 432 k) were used for training, revealing a strong dependence of model performance on data volume. Outlier reduction methods, such as dose averaging and data reduction near the center, were applied, reducing the max-min RD range by a factor of 3 to 10. From the results, the potential and necessity of an AI dose estimation model for more complicated geometries, such as those involving anthropomorphic phantoms, were discussed. • The feasibility of a deep-learning model for dose conversion in retrospective dosimetry was investigated. • A slab phantom and glass plates, assumed to represent a human body and fortuitous dosimeters, respectively, were used. • Dose conversion coefficients from the Monte Carlo simulation were compared with those from the deep-learning model.

Radiation MeasurementsVol. 181
Korea Atomic Energy Research Institute (KR)
Ministry of Science and ICT, South Korea
Openalex Percentile: Top 10%
Advanced Radiotherapy Techniques
3.77
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.