Development and validation of rp-hplc method for simultaneous estimation of imeglimin and metformin used for The treatment of diabetes

A rapid and precise reverse phase high performance liquid chromatographic method has been developed for the validated of Imeglimin And Metformin, in its pure form as well as in tablet dosage form. Chromatography was carried out on a Hypersil C18 (4.6×250mm) 5µ column using a mixture of Water and Acetonitrile (50:50) as the mobile phase at a flow rate of 1.0ml/min, the detection was carried out at 244nm. The retention time of the Imeglimin and Metformin was 2.0, 4.0±0.02min respectively. The method produce linear responses in the concentration range of 20-100µg/ml of Imeglimin and 40-200µg/ml of Metformin. The method precision for the determination of assay was below 2.0%RSD. The method is useful in the quality control of bulk and pharmaceutical formulations.

Authors

Institutions

Publication Details

Journal
International Journal of Allied Medical Sciences and Clinical Research
Published
2024-10-17
DOI
https://doi.org/10.61096/ijamscr.v12.iss4.2024.454-463
Primary Topic
Computational Drug Discovery Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and validation of rp-hplc method for simultaneous estimation of imeglimin and metformin used for The treatment of diabetes

Gorantla Nagamallika, A. Krishna Sailaja
International Journal of Allied Medical Sciences and Clinical Research
Computational Drug Discovery Methods
article

Development and validation of rp-hplc method for simultaneous estimation of imeglimin and metformin used for The treatment of diabetes

Gorantla Nagamallika, A. Krishna Sailaja
article en

Abstract

A rapid and precise reverse phase high performance liquid chromatographic method has been developed for the validated of Imeglimin And Metformin, in its pure form as well as in tablet dosage form. Chromatography was carried out on a Hypersil C18 (4.6×250mm) 5µ column using a mixture of Water and Acetonitrile (50:50) as the mobile phase at a flow rate of 1.0ml/min, the detection was carried out at 244nm. The retention time of the Imeglimin and Metformin was 2.0, 4.0±0.02min respectively. The method produce linear responses in the concentration range of 20-100µg/ml of Imeglimin and 40-200µg/ml of Metformin. The method precision for the determination of assay was below 2.0%RSD. The method is useful in the quality control of bulk and pharmaceutical formulations.

International Journal of Allied Medical Sciences and Clinical ResearchVol. 12(4)
Omega Consult (Slovenia) (SI)
Clean water and sanitation
Openalex Percentile: Top 70%
Computational Drug Discovery Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.