Analysis of the Effect of Skin Pigmentation and Oxygen Saturation on Monte Carlo-Simulated Reflectance Photoplethysmography Signals

The effect of skin pigmentation on photoplethysmography and, specifically, pulse oximetry has recently received a significant amount of attention amongst researchers, especially since the COVID-19 pandemic. With most computational studies observing overestimation of arterial oxygen saturation (SpO<sub>2</sub>) in individuals with darker skin, this study seeks to further investigate the root causes of these discrepancies. This study analysed intensity changes from Monte Carlo-simulated reflectance PPG signals across light, moderate, and dark skin types at oxygen saturations of 70% and 100% in MATLAB R2024a. With simulated intensity reflecting PPG amplitude, the results showed that systolic intensity decreased by 3-4% as pigmentation increased at 660 nm. It was also shown that the impact at 940 nm is minimal (<0.2%), indicating that the increased absorption of red light by melanin has a greater effect on the ratio of ratios calculations. These results suggest that in-built adjustments may be required for data collected from red-light sources in pulse oximeters that do not currently have the necessary post-processing algorithms to account for this difference between diverse skin populations.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-01-10
DOI
https://doi.org/10.3390/s25020372
Citations
5
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
3.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the Effect of Skin Pigmentation and Oxygen Saturation on Monte Carlo-Simulated Reflectance Photoplethysmography Signals

Meha Qassem, Raghda Al-Halawani, P. A. Kyriacou
5 citations
Sensors
Non-Invasive Vital Sign Monitoring
3.37
article

Analysis of the Effect of Skin Pigmentation and Oxygen Saturation on Monte Carlo-Simulated Reflectance Photoplethysmography Signals

Meha Qassem, Raghda Al-Halawani, P. A. Kyriacou
article en
5 citations

Abstract

The effect of skin pigmentation on photoplethysmography and, specifically, pulse oximetry has recently received a significant amount of attention amongst researchers, especially since the COVID-19 pandemic. With most computational studies observing overestimation of arterial oxygen saturation (SpO<sub>2</sub>) in individuals with darker skin, this study seeks to further investigate the root causes of these discrepancies. This study analysed intensity changes from Monte Carlo-simulated reflectance PPG signals across light, moderate, and dark skin types at oxygen saturations of 70% and 100% in MATLAB R2024a. With simulated intensity reflecting PPG amplitude, the results showed that systolic intensity decreased by 3-4% as pigmentation increased at 660 nm. It was also shown that the impact at 940 nm is minimal (<0.2%), indicating that the increased absorption of red light by melanin has a greater effect on the ratio of ratios calculations. These results suggest that in-built adjustments may be required for data collected from red-light sources in pulse oximeters that do not currently have the necessary post-processing algorithms to account for this difference between diverse skin populations.

SensorsVol. 25(2)
St George's, University of London (GB), City St George's, University of London (GB)
Good health and well-being
Openalex Percentile: Top 9%
Non-Invasive Vital Sign Monitoring
3.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.