A multi-method comparison of body volume and body fat in healthy adults: source of caution for interchangeability of techniques

BACKGROUND AND AIM: The interchangeability of different techniques for volume measurements makes it important to cross-calibrate volumes from different scanning systems against a gold standard Air Displacement Plethysmography (ADP), and identify possible causes of the differences. MATERIALS AND METHODS: A sample of 121 adults (78 males and 43 females, aged 18 – 44 y underwent body volume measurement via ADP (Bodpod system, Cosmed, Rome, Italy) and 3D scanning using portable scanner (Artec L, Artec Luxembourg) and fixed laser scanner (Hamamatsu BLS, Hamamatsu, Japan). Duplicate measurements were undertaken in 12 participants. RESULTS: Measurements were highly correlated between techniques for volume (R=0.989; 0.977 and 0.979; P<0.0001) and inter-technique errors for volumes and girths were <1% technical error of measurement. Bland and Altman analysis revealed volume measurements differed between Hamamatsu and both Artec and Bodpod (P<0.05), but were similar between Artec and Bodpod (P>0.05) and these patterns remained when volumes were converted into %fat. There were no significant differences between anthropometric and 3DS-extracted waist and hip girths for either scanner type (P>0.05). CONCLUSION: Despite their comparability for extracted waist and hip girth, the scanners are not interchangeable for volume and %fat estimation.

Authors

Institutions

Publication Details

Journal
Journal of Experimental and Clinical Anatomy
Published
2024-12-31
DOI
https://doi.org/10.4314/jeca.v21i2.14
Primary Topic
Body Composition Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A multi-method comparison of body volume and body fat in healthy adults: source of caution for interchangeability of techniques

C.O. Njoku, Arthur D. Stewart, E.E. Besong
Journal of Experimental and Clinical Anatomy
Body Composition Measurement Techniques
article

A multi-method comparison of body volume and body fat in healthy adults: source of caution for interchangeability of techniques

C.O. Njoku, Arthur D. Stewart, E.E. Besong
article en

Abstract

BACKGROUND AND AIM: The interchangeability of different techniques for volume measurements makes it important to cross-calibrate volumes from different scanning systems against a gold standard Air Displacement Plethysmography (ADP), and identify possible causes of the differences. MATERIALS AND METHODS: A sample of 121 adults (78 males and 43 females, aged 18 – 44 y underwent body volume measurement via ADP (Bodpod system, Cosmed, Rome, Italy) and 3D scanning using portable scanner (Artec L, Artec Luxembourg) and fixed laser scanner (Hamamatsu BLS, Hamamatsu, Japan). Duplicate measurements were undertaken in 12 participants. RESULTS: Measurements were highly correlated between techniques for volume (R=0.989; 0.977 and 0.979; P<0.0001) and inter-technique errors for volumes and girths were <1% technical error of measurement. Bland and Altman analysis revealed volume measurements differed between Hamamatsu and both Artec and Bodpod (P<0.05), but were similar between Artec and Bodpod (P>0.05) and these patterns remained when volumes were converted into %fat. There were no significant differences between anthropometric and 3DS-extracted waist and hip girths for either scanner type (P>0.05). CONCLUSION: Despite their comparability for extracted waist and hip girth, the scanners are not interchangeable for volume and %fat estimation.

Journal of Experimental and Clinical AnatomyVol. 21(2)
Robert Gordon University (GB), Ebonyi State University (NG)
Tertiary Education Trust Fund
Openalex Percentile: Top 65%
Body Composition Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.