Simulation and analysis of heat transfer in counter-flow helical double-pipe heat exchangers using CFD

Heat exchangers play a vital role in industrial applications by facilitating efficient thermal energy exchange between two distinct fluid streams. These fluids are separated by a solid barrier, which prevents mixing, conserves energy and reduces operational costs. To enhance the efficiency of heat exchangers, wire inserts are often incorporated into the fluid paths. These inserts increase turbulence, improve fluid mixing, and boost heat transfer rates, making the system more effective. In this study, a counter-flow helical double-pipe heat exchanger was analyzed using Computational Fluid Dynamics (CFD) through the simulation software Ansys CFX. The simulations were conducted for cold fluid temperatures ranging from 12°C to 22°C and hot fluid temperatures between 32°C and 52°C, with Reynolds numbers varying from [Formula: see text] to [Formula: see text] to capture a broad spectrum of flow behaviors. The CFD model demonstrated excellent agreement with experimental results, achieving high correlation coefficients of 0.96 for the hot fluid and 0.95 for the cold fluid. This high level of accuracy validates the robustness of the model in predicting real-world heat transfer dynamics. The inclusion of wire inserts within the cold fluid flow path played a critical role in enhancing heat exchanger performance. By inducing turbulence, the wire inserts disrupted the thermal boundary layer, allowing for greater heat transfer between the hot and cold streams. This resulted in a substantial improvement in heat transfer rates, reaching a 25% increase under optimized conditions. This also led to an improved temperature difference between the fluid at the inlet and outlet, optimizing the thermal performance of the exchanger. Alternative materials such as aluminum or titanium could also be considered for wire inserts, potentially improving thermal efficiency at varying costs.

Authors

Institutions

Publication Details

Journal
International Journal of Modern Physics C
Published
2025-01-10
DOI
https://doi.org/10.1142/s0129183125500433
Citations
15
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
10.70
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation and analysis of heat transfer in counter-flow helical double-pipe heat exchangers using CFD

Shital Yashwant Waware, Parimal Sharad Bhambare, Anant Sidhappa Kurhade, Sushil Deshpande et al.
15 citations
International Journal of Modern Physics C
Heat Transfer and Optimization
10.70
article

Simulation and analysis of heat transfer in counter-flow helical double-pipe heat exchangers using CFD

Shital Yashwant Waware, Parimal Sharad Bhambare, Anant Sidhappa Kurhade, Sushil Deshpande, G. Murali, Pushparaj Warke, Gulab Dattrao Siraskar
article en
15 citations

Abstract

Heat exchangers play a vital role in industrial applications by facilitating efficient thermal energy exchange between two distinct fluid streams. These fluids are separated by a solid barrier, which prevents mixing, conserves energy and reduces operational costs. To enhance the efficiency of heat exchangers, wire inserts are often incorporated into the fluid paths. These inserts increase turbulence, improve fluid mixing, and boost heat transfer rates, making the system more effective. In this study, a counter-flow helical double-pipe heat exchanger was analyzed using Computational Fluid Dynamics (CFD) through the simulation software Ansys CFX. The simulations were conducted for cold fluid temperatures ranging from 12°C to 22°C and hot fluid temperatures between 32°C and 52°C, with Reynolds numbers varying from [Formula: see text] to [Formula: see text] to capture a broad spectrum of flow behaviors. The CFD model demonstrated excellent agreement with experimental results, achieving high correlation coefficients of 0.96 for the hot fluid and 0.95 for the cold fluid. This high level of accuracy validates the robustness of the model in predicting real-world heat transfer dynamics. The inclusion of wire inserts within the cold fluid flow path played a critical role in enhancing heat exchanger performance. By inducing turbulence, the wire inserts disrupted the thermal boundary layer, allowing for greater heat transfer between the hot and cold streams. This resulted in a substantial improvement in heat transfer rates, reaching a 25% increase under optimized conditions. This also led to an improved temperature difference between the fluid at the inlet and outlet, optimizing the thermal performance of the exchanger. Alternative materials such as aluminum or titanium could also be considered for wire inserts, potentially improving thermal efficiency at varying costs.

International Journal of Modern Physics CVol. 36(12)
Dr. D. Y. Patil Medical College, Hospital and Research Centre (IN), Muscat College (OM), Dr D Y Patil Dental College & Hospital (IN), Koneru Lakshmaiah Education Foundation (IN)
Affordable and clean energy
Openalex Percentile: Top 1%
Heat Transfer and Optimization
10.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.