Laboratory validation of patient-specific templating for total knee arthroplasty

Patient-specific templating (PST), which is a sister procedure to patient-specific instrumentation (PSI) but hospital-based, is relatively less complex and less expensive than robotics and navigation. However, there are some concerns about the PST including the process of preoperative planning, 3D printing and material, positioning of PST intraoperatively, availability, and clinical value. The purpose of this study was to validate the technical accuracy and reliability of the PST technique in the lab and to report the outcomes of clinical application. To test the reliability of the PST technique, five observers positioned the PST templates five times over the distal femur and proximal tibial whilst a navigation system was used to measure the level of bone cutting, coronal and sagittal alignment, and rotation in both femur and tibia. The mean alignment error in all planes was 0.67° (maximum 2.5°). Concerning the bone (femoral and tibial) cutting, the mean error was 0.32 mm (maximum 1 mm). The qualitative and quantitative analysis showed an overall agreement between observers (p < 0.05). The laboratory part of this study showed that the positioning of the PST over the proximal tibia and distal femur during TKA is reliable. There were statistically insignificant intraobserver and interobserver variations.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-01-10
DOI
https://doi.org/10.1038/s41598-024-77794-9
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Laboratory validation of patient-specific templating for total knee arthroplasty

Branislav Jaramaz, Mahmoud A. Hafez, Arne Jansen, Frank Portheine
Scientific Reports
Total Knee Arthroplasty Outcomes
article

Laboratory validation of patient-specific templating for total knee arthroplasty

Branislav Jaramaz, Mahmoud A. Hafez, Arne Jansen, Frank Portheine
article en

Abstract

Patient-specific templating (PST), which is a sister procedure to patient-specific instrumentation (PSI) but hospital-based, is relatively less complex and less expensive than robotics and navigation. However, there are some concerns about the PST including the process of preoperative planning, 3D printing and material, positioning of PST intraoperatively, availability, and clinical value. The purpose of this study was to validate the technical accuracy and reliability of the PST technique in the lab and to report the outcomes of clinical application. To test the reliability of the PST technique, five observers positioned the PST templates five times over the distal femur and proximal tibial whilst a navigation system was used to measure the level of bone cutting, coronal and sagittal alignment, and rotation in both femur and tibia. The mean alignment error in all planes was 0.67° (maximum 2.5°). Concerning the bone (femoral and tibial) cutting, the mean error was 0.32 mm (maximum 1 mm). The qualitative and quantitative analysis showed an overall agreement between observers (p < 0.05). The laboratory part of this study showed that the positioning of the PST over the proximal tibia and distal femur during TKA is reliable. There were statistically insignificant intraobserver and interobserver variations.

Scientific ReportsVol. 15(1)
October 6 University (EG), Carnegie Mellon University (US)
Openalex Percentile: Top 99%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.