Dual-Gas Sensor Employing Wavelength-Stabilized Tunable Diode Laser Absorption Spectroscopy and H-Infinity Filtering Algorithm

A compact dual-gas sensor based on the two near-infrared distributed feedback diode lasers and a multipass cell has been established for the simultaneous measurement of methane (CH<sub>4</sub>) and acetylene (C<sub>2</sub>H<sub>2</sub>). The time division multiplexing calibration-free direct absorption spectroscopy is used to eliminate the cross interference in the application of multicomponent gas sensors. A wavelength stabilization technique based on the proportion integration differentiation feedback control is developed to suppress laser wavelength drift and an H-infinity (H<sub>∞</sub>) filter algorithm to reduce the system noise. The results show that the detection sensitivity of CH<sub>4</sub> and C<sub>2</sub>H<sub>2</sub> reaches 39.9 parts per billion (ppb) and 47.3 ppb in the optimal integration time of 556 s and 312 s, respectively. In addition, the 31 consecutive hours measured results of CH<sub>4</sub> in outdoor ambient air show that the proposed detection technology is very suitable for high-precision in-situ measurement of trace gases.

Authors

Institutions

Publication Details

Journal
Applied Spectroscopy
Published
2025-01-10
DOI
https://doi.org/10.1177/00037028241310463
Citations
3
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
2.27
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual-Gas Sensor Employing Wavelength-Stabilized Tunable Diode Laser Absorption Spectroscopy and H-Infinity Filtering Algorithm

Qiang Ge, Qiannan Cai, Linguang Xu, Gang Zhang et al.
3 citations
Applied Spectroscopy
Spectroscopy and Laser Applications
2.27
article

Dual-Gas Sensor Employing Wavelength-Stabilized Tunable Diode Laser Absorption Spectroscopy and H-Infinity Filtering Algorithm

Qiang Ge, Qiannan Cai, Linguang Xu, Gang Zhang, Dongyun Xu
article en
3 citations

Abstract

A compact dual-gas sensor based on the two near-infrared distributed feedback diode lasers and a multipass cell has been established for the simultaneous measurement of methane (CH<sub>4</sub>) and acetylene (C<sub>2</sub>H<sub>2</sub>). The time division multiplexing calibration-free direct absorption spectroscopy is used to eliminate the cross interference in the application of multicomponent gas sensors. A wavelength stabilization technique based on the proportion integration differentiation feedback control is developed to suppress laser wavelength drift and an H-infinity (H<sub>∞</sub>) filter algorithm to reduce the system noise. The results show that the detection sensitivity of CH<sub>4</sub> and C<sub>2</sub>H<sub>2</sub> reaches 39.9 parts per billion (ppb) and 47.3 ppb in the optimal integration time of 556 s and 312 s, respectively. In addition, the 31 consecutive hours measured results of CH<sub>4</sub> in outdoor ambient air show that the proposed detection technology is very suitable for high-precision in-situ measurement of trace gases.

Applied SpectroscopyVol. 79(8)
Anhui Polytechnic University (CN)
Affordable and clean energy
Openalex Percentile: Top 15%
Spectroscopy and Laser Applications
2.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Dual-Gas Sensor Employing Wavelength-Stabilized Tunable Diode Laser Absorption Spectroscopy and H-Infinity Filtering Algorithm — Qiang Ge, Qiannan Cai, et al. · Applied Spectroscopy (2025) | TGRS Research Map | TGRS