Application of spectrophotometric method for antibiotic Cefotaxime detection in a model solution

The number of studies on the detection of antibiotics in urban wastewater and in surface waterbodies is increasing every year, as the increase of antibiotic-resistance of microorganisms is one of the most urgent public health problems. This paper presents the results of study on the detection of the antibiotic Cefotaxime (CFX) in model solutions using the spectrophotometric method. In several series of experiments we determined the minimal CFX concentrations in the model solutions, which can be detected with the spectrophotometer PE-5400 UV. The optical density peak in the ultraviolet range at 300 nm is established. The shift of absorption spectrum from 300 to 280 nm in the model solution samples with increasing storage time of the solution was fixed. We determined the CFX peculiarities: increase of optical density peak in samples at pH shift to acidic medium, especially at pH values from 0.2 to 2.0 as well as reduction of the optical density peak with minimum pH values from 6.0 to 6.4 in the wavelength range from 280 to 300 nm. The effect of metal ions added to the model solution of CFX is considered in detail. The results of two series of experiments are presented, in which the possibility of complex compounds with Al3+, Zn2+, Cu2+, Pb2+ formation was determined by changing the concentration ratios of CFX and metal ions. There was an increase in optical density in samples with Zn2+, Cu2+, Pb2+ with increasing in metal ions content. In model solutions with Al3+ and Fe3+ there was no change in optical density. The obtained values of optical density and absorption spectra of CFX model solution can be used when developing methods of antibiotic detection in various media, including urban wastewater.

Authors

Publication Details

Journal
Theoretical and Applied Ecology
Published
2024-12-23
DOI
https://doi.org/10.25750/1995-4301-2024-4-064-072
Primary Topic
Antibiotics Pharmacokinetics and Efficacy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of spectrophotometric method for antibiotic Cefotaxime detection in a model solution

V. G. ISAKOV, E V Grakhova, M Y Dyagelev, A M Nepogodin et al.
Theoretical and Applied Ecology
Antibiotics Pharmacokinetics and Efficacy
article

Application of spectrophotometric method for antibiotic Cefotaxime detection in a model solution

V. G. ISAKOV, E V Grakhova, M Y Dyagelev, A M Nepogodin, A. A. Abramova, A. M. Batueva
article en

Abstract

The number of studies on the detection of antibiotics in urban wastewater and in surface waterbodies is increasing every year, as the increase of antibiotic-resistance of microorganisms is one of the most urgent public health problems. This paper presents the results of study on the detection of the antibiotic Cefotaxime (CFX) in model solutions using the spectrophotometric method. In several series of experiments we determined the minimal CFX concentrations in the model solutions, which can be detected with the spectrophotometer PE-5400 UV. The optical density peak in the ultraviolet range at 300 nm is established. The shift of absorption spectrum from 300 to 280 nm in the model solution samples with increasing storage time of the solution was fixed. We determined the CFX peculiarities: increase of optical density peak in samples at pH shift to acidic medium, especially at pH values from 0.2 to 2.0 as well as reduction of the optical density peak with minimum pH values from 6.0 to 6.4 in the wavelength range from 280 to 300 nm. The effect of metal ions added to the model solution of CFX is considered in detail. The results of two series of experiments are presented, in which the possibility of complex compounds with Al3+, Zn2+, Cu2+, Pb2+ formation was determined by changing the concentration ratios of CFX and metal ions. There was an increase in optical density in samples with Zn2+, Cu2+, Pb2+ with increasing in metal ions content. In model solutions with Al3+ and Fe3+ there was no change in optical density. The obtained values of optical density and absorption spectra of CFX model solution can be used when developing methods of antibiotic detection in various media, including urban wastewater.

Theoretical and Applied Ecology(4)
Openalex Percentile: Top 75%
Antibiotics Pharmacokinetics and Efficacy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.