Assessing the Air Quality Impact of Train Operation at Tokyo Metro Shibuya Station from Portable Sensor Data

Air pollution remains a critical global health concern, with 91% of the world’s population exposed to air quality exceeding World Health Organization (WHO) standards and indoor pollution causing approximately 3.8 million deaths annually due to incomplete fuel combustion. Subways, as major public transportation modes in densely populated cities, can exhibit fine particulate matter (PM) levels that surpass safety limits, even in developed countries. Contributing factors include station location, ambient air quality, train frequency, ventilation efficiency, braking systems, tunnel structure, and electrical components. While elevated PM levels in underground platforms are recognized, the vertical and horizontal variations within stations are not well understood. This study examines the vertical and horizontal distribution of PM2.5 and PM10 levels at Shibuya Station, a structurally complex hub in the Tokyo Subway System. Portable sensors were employed to measure PM concentrations across different platform levels—both above and underground—and at various locations along the platforms. The results indicate that above-ground platforms have significantly lower PM2.5 and PM10 levels compared to underground platforms (17.09 μg/m3 vs. 22.73 μg/m3 for PM2.5; 39.54 μg/m3 vs. 56.98 μg/m3 for PM10). Notably, the highest pollution levels were found not at the deepest platform but at the one with the least effective ventilation. On the same platform, PM levels varied by up to 63.72% for PM2.5 and 120.23% for PM10, with elevated concentrations near the platform extremities compared to central areas. These findings suggest that ventilation efficiency plays a more significant role than elevation in vertical PM variation, while horizontal differences are likely influenced by piston effects from moving trains. This study underscores the risk of exposure to unsafe PM2.5 levels in underground platforms, particularly at platform extremities, highlighting the need for improved ventilation strategies to enhance air quality in subway environments.

Authors

Institutions

Publication Details

Journal
Remote Sensing
Published
2025-01-10
DOI
https://doi.org/10.3390/rs17020235
Citations
5
Primary Topic
Air Quality and Health Impacts
Type
article
Field-Weighted Citation Impact
6.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing the Air Quality Impact of Train Operation at Tokyo Metro Shibuya Station from Portable Sensor Data

Wataru Takeuchi, Xuan Truong Trinh, Deepanshu Agarwal
5 citations
Remote Sensing
Air Quality and Health Impacts
6.00
article

Assessing the Air Quality Impact of Train Operation at Tokyo Metro Shibuya Station from Portable Sensor Data

Wataru Takeuchi, Xuan Truong Trinh, Deepanshu Agarwal
article en
5 citations

Abstract

Air pollution remains a critical global health concern, with 91% of the world’s population exposed to air quality exceeding World Health Organization (WHO) standards and indoor pollution causing approximately 3.8 million deaths annually due to incomplete fuel combustion. Subways, as major public transportation modes in densely populated cities, can exhibit fine particulate matter (PM) levels that surpass safety limits, even in developed countries. Contributing factors include station location, ambient air quality, train frequency, ventilation efficiency, braking systems, tunnel structure, and electrical components. While elevated PM levels in underground platforms are recognized, the vertical and horizontal variations within stations are not well understood. This study examines the vertical and horizontal distribution of PM2.5 and PM10 levels at Shibuya Station, a structurally complex hub in the Tokyo Subway System. Portable sensors were employed to measure PM concentrations across different platform levels—both above and underground—and at various locations along the platforms. The results indicate that above-ground platforms have significantly lower PM2.5 and PM10 levels compared to underground platforms (17.09 μg/m3 vs. 22.73 μg/m3 for PM2.5; 39.54 μg/m3 vs. 56.98 μg/m3 for PM10). Notably, the highest pollution levels were found not at the deepest platform but at the one with the least effective ventilation. On the same platform, PM levels varied by up to 63.72% for PM2.5 and 120.23% for PM10, with elevated concentrations near the platform extremities compared to central areas. These findings suggest that ventilation efficiency plays a more significant role than elevation in vertical PM variation, while horizontal differences are likely influenced by piston effects from moving trains. This study underscores the risk of exposure to unsafe PM2.5 levels in underground platforms, particularly at platform extremities, highlighting the need for improved ventilation strategies to enhance air quality in subway environments.

Remote SensingVol. 17(2)
The University of Tokyo (JP)
Openalex Percentile: Top 5%
Air Quality and Health Impacts
6.00
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.