A novel hollow-core antiresonant fiber-based biosensor for blood component detection in the THz regime

This article proposes a novel biosensor based on a five-semi-circular cladding tube hollow core antiresonant fiber (HC-ARF) with a frequency range of 0.5-2.8 THz, using Zeonex as the background material. The HC-ARF biosensor analyses various blood components, namely water, plasma, white blood cells (WBC), hemoglobin (HB), and red blood cells (RBC). We utilized COMSOL Multiphysics to perform the numerical analysis of the sensor model. For water, plasma, WBC, HB, and RBC, the proposed HC-ARF biosensor exhibits the highest sensitivity levels of 99.50%, 99.58%, 99.43%, 99.58%, and 99.46%, respectively. Furthermore, it demonstrates confinement loss (CL) and effective material loss (EML) of 1.3 × 10<sup>-3</sup>dBcm<sup>-1</sup>and 5.3 × 10<sup>-5</sup>dBcm<sup>-1</sup>, respectively.

Authors

Institutions

Publication Details

Journal
Biomedical Physics & Engineering Express
Published
2025-01-10
DOI
https://doi.org/10.1088/2057-1976/ada88a
Citations
2
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel hollow-core antiresonant fiber-based biosensor for blood component detection in the THz regime

Maharaja Balaji, Sathiyan Samikannu
2 citations
Biomedical Physics & Engineering Express
Advanced Fiber Optic Sensors
1.46
article

A novel hollow-core antiresonant fiber-based biosensor for blood component detection in the THz regime

Maharaja Balaji, Sathiyan Samikannu
article en
2 citations

Abstract

This article proposes a novel biosensor based on a five-semi-circular cladding tube hollow core antiresonant fiber (HC-ARF) with a frequency range of 0.5-2.8 THz, using Zeonex as the background material. The HC-ARF biosensor analyses various blood components, namely water, plasma, white blood cells (WBC), hemoglobin (HB), and red blood cells (RBC). We utilized COMSOL Multiphysics to perform the numerical analysis of the sensor model. For water, plasma, WBC, HB, and RBC, the proposed HC-ARF biosensor exhibits the highest sensitivity levels of 99.50%, 99.58%, 99.43%, 99.58%, and 99.46%, respectively. Furthermore, it demonstrates confinement loss (CL) and effective material loss (EML) of 1.3 × 10<sup>-3</sup>dBcm<sup>-1</sup>and 5.3 × 10<sup>-5</sup>dBcm<sup>-1</sup>, respectively.

Biomedical Physics & Engineering ExpressVol. 11(2)
SRM Institute of Science and Technology (IN)
Clean water and sanitation
Openalex Percentile: Top 20%
Advanced Fiber Optic Sensors
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A novel hollow-core antiresonant fiber-based biosensor for blood component detection in the THz regime — Maharaja Balaji, Sathiyan Samikannu · Biomedical Physics & Engineering Express (2025) | TGRS Research Map | TGRS