Functional Mobility Assessment after Unilateral Knee Arthroplasty: A Comparative Study of Two Prosthesis Types

Aims: To evaluate and compare the functional mobility of patients undergoing unilateral knee arthroplasty using two prostheses: fixed tibial plateau and rotating platform. This study addresses a gap in the existing literature by providing detailed insights into functional mobility patterns and prosthesis-specific outcomes. Study Design: A prospective, observational, and comparative study with assessments conducted at two-time points: 12 to 24 months after surgery. Place and Duration of Study: Conducted at a tertiary hospital for rehabilitation and readaptation, in partnership with a private university from March 2022 to December 2024. Methodology: Thirty-six patients who had previously undergone unilateral knee arthroplasty were included, equally divided between fixed and rotating platform prostheses. The Timed Up and Go (TUG) test, performed with the G-WALK inertial sensor, captured 15 functional mobility variables across two time points. Statistical analyses included variance tests and correlations to identify changes between time points and groups. Results: The mean TUG time increased from 14.47 ± 3.03 seconds to 15.24 ± 3.85 seconds without statistical significance (P=.301). However, the Sit-to-Stand phase significantly reduced duration (P=.036). The turning phase demonstrated significant improvements in both duration (P<.001) and speed (P<.001). No statistically significant differences were observed between prosthesis types in most variables. The comparison between fixed and rotating platform prostheses is clinically important as it provides insights for tailoring postoperative rehabilitation strategies. Conclusion: Fixed and rotating platform prostheses demonstrated comparable functional performance, with specific improvements noted over time. The findings emphasize the value of inertial sensors in conducting detailed clinical assessments and suggest opportunities for further research to enhance prosthesis selection and rehabilitation protocols. This study contributes to clinical practice by offering evidence that supports personalized rehabilitation strategies.

Authors

Institutions

Publication Details

Journal
Journal of Advances in Medicine and Medical Research
Published
2025-01-09
DOI
https://doi.org/10.9734/jammr/2025/v37i15695
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Functional Mobility Assessment after Unilateral Knee Arthroplasty: A Comparative Study of Two Prosthesis Types

Helder Rocha da Silva Araújo, Marcelo Rodrigues Torres, Rodolfo Borges Parreira, Leonardo Pinheiro Rezende et al.
Journal of Advances in Medicine and Medical Research
Total Knee Arthroplasty Outcomes
article

Functional Mobility Assessment after Unilateral Knee Arthroplasty: A Comparative Study of Two Prosthesis Types

Helder Rocha da Silva Araújo, Marcelo Rodrigues Torres, Rodolfo Borges Parreira, Leonardo Pinheiro Rezende, Cláudia Santos Oliveira, Andrei Machado Viegas da Trindade, Ulric Araújo Vitória
article en

Abstract

Aims: To evaluate and compare the functional mobility of patients undergoing unilateral knee arthroplasty using two prostheses: fixed tibial plateau and rotating platform. This study addresses a gap in the existing literature by providing detailed insights into functional mobility patterns and prosthesis-specific outcomes. Study Design: A prospective, observational, and comparative study with assessments conducted at two-time points: 12 to 24 months after surgery. Place and Duration of Study: Conducted at a tertiary hospital for rehabilitation and readaptation, in partnership with a private university from March 2022 to December 2024. Methodology: Thirty-six patients who had previously undergone unilateral knee arthroplasty were included, equally divided between fixed and rotating platform prostheses. The Timed Up and Go (TUG) test, performed with the G-WALK inertial sensor, captured 15 functional mobility variables across two time points. Statistical analyses included variance tests and correlations to identify changes between time points and groups. Results: The mean TUG time increased from 14.47 ± 3.03 seconds to 15.24 ± 3.85 seconds without statistical significance (P=.301). However, the Sit-to-Stand phase significantly reduced duration (P=.036). The turning phase demonstrated significant improvements in both duration (P<.001) and speed (P<.001). No statistically significant differences were observed between prosthesis types in most variables. The comparison between fixed and rotating platform prostheses is clinically important as it provides insights for tailoring postoperative rehabilitation strategies. Conclusion: Fixed and rotating platform prostheses demonstrated comparable functional performance, with specific improvements noted over time. The findings emphasize the value of inertial sensors in conducting detailed clinical assessments and suggest opportunities for further research to enhance prosthesis selection and rehabilitation protocols. This study contributes to clinical practice by offering evidence that supports personalized rehabilitation strategies.

Journal of Advances in Medicine and Medical ResearchVol. 37(1)
Universidade Evangelica de Goiás (BR)
Partnerships for the goals
Openalex Percentile: Top 99%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.