Biomechanical Assessment of Patients with Unilateral Total Knee Arthroplasty: A Preliminary Comparative Study

Aims: To identify the biomechanical differences between two types of prostheses (posterior-stabilized prosthesis with a fixed tibial plateau base and congruent prosthesis with a rotating tibial plateau) through functional performance measured by the 2-Minute Walk Test using the G-Sensor® inertial sensor (BTS Bioengineering S.p.A., Italy). Study Design: A prospective, observational, and comparative study with assessments conducted at two time points: 12 to 24 months after surgery. Place and Duration of Study: This study was carried out in a tertiary hospital in collaboration with a private university in the state of Goiás, Brazil, between March 2022 and December 2024. Methodology: This study evaluates and compares the functional performance of a sample of 36 patients using the 2-Minute Walk Test (2MWT) with an inertial sensor at two distinct time points, 12 to 24 months postoperatively. Patients were characterized by age, sex, BMI, postoperative time, laterality of the operated knee, and type of prosthesis used (fixed plateau or mobile plateau). Results: The study included 36 participants (21 women and 15 men; mean age 69.38 years, BMI 30.46), with 24 undergoing right knee arthroplasty. Half received fixed, and half rotated tibial plateau prostheses. Postoperative assessments at 17.31 and 42.80 months showed no significant differences in gait parameters between prosthesis types or sides. Pearson’s correlation revealed a strong negative relationship between test duration, cadence, and speed for rotating prostheses (r = -0.67/-0.66, P =.001) and between duration and speed for fixed prostheses (r = -0.8, P<.001). Conclusion: This study found no significant functional differences between fixed and rotating tibial plateau prostheses using the 2-Minute Walk Test. Both implants effectively restored knee mobility, emphasizing the utility of inertial sensors for clinical assessment. Further research with larger samples is needed to confirm these findings.

Authors

Institutions

Publication Details

Journal
Journal of Advances in Medicine and Medical Research
Published
2025-01-09
DOI
https://doi.org/10.9734/jammr/2025/v37i15696
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical Assessment of Patients with Unilateral Total Knee Arthroplasty: A Preliminary Comparative Study

Eraldo L. Batista, Rodolfo Borges Parreira, Leonardo Pinheiro Rezende, Cláudia Santos Oliveira et al.
1 links
Journal of Advances in Medicine and Medical Research
Total Knee Arthroplasty Outcomes
article

Biomechanical Assessment of Patients with Unilateral Total Knee Arthroplasty: A Preliminary Comparative Study

Eraldo L. Batista, Rodolfo Borges Parreira, Leonardo Pinheiro Rezende, Cláudia Santos Oliveira, Andrei Machado Viegas da Trindade, F. Garcia, Cícero Antônio Dos Santos Júnior, Gabriel Souza Camargo
article en

Abstract

Aims: To identify the biomechanical differences between two types of prostheses (posterior-stabilized prosthesis with a fixed tibial plateau base and congruent prosthesis with a rotating tibial plateau) through functional performance measured by the 2-Minute Walk Test using the G-Sensor® inertial sensor (BTS Bioengineering S.p.A., Italy). Study Design: A prospective, observational, and comparative study with assessments conducted at two time points: 12 to 24 months after surgery. Place and Duration of Study: This study was carried out in a tertiary hospital in collaboration with a private university in the state of Goiás, Brazil, between March 2022 and December 2024. Methodology: This study evaluates and compares the functional performance of a sample of 36 patients using the 2-Minute Walk Test (2MWT) with an inertial sensor at two distinct time points, 12 to 24 months postoperatively. Patients were characterized by age, sex, BMI, postoperative time, laterality of the operated knee, and type of prosthesis used (fixed plateau or mobile plateau). Results: The study included 36 participants (21 women and 15 men; mean age 69.38 years, BMI 30.46), with 24 undergoing right knee arthroplasty. Half received fixed, and half rotated tibial plateau prostheses. Postoperative assessments at 17.31 and 42.80 months showed no significant differences in gait parameters between prosthesis types or sides. Pearson’s correlation revealed a strong negative relationship between test duration, cadence, and speed for rotating prostheses (r = -0.67/-0.66, P =.001) and between duration and speed for fixed prostheses (r = -0.8, P<.001). Conclusion: This study found no significant functional differences between fixed and rotating tibial plateau prostheses using the 2-Minute Walk Test. Both implants effectively restored knee mobility, emphasizing the utility of inertial sensors for clinical assessment. Further research with larger samples is needed to confirm these findings.

Journal of Advances in Medicine and Medical ResearchVol. 37(1)
Universidade Evangelica de Goiás (BR)
Openalex Percentile: Top 99%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.