Research on Heart Rate Detection from Facial Videos Based on an Attention Mechanism 3D Convolutional Neural Network

Remote photoplethysmography (rPPG) has attracted growing attention due to its non-contact nature. However, existing non-contact heart rate detection methods are often affected by noise from motion artifacts and changes in lighting, which can lead to a decrease in detection accuracy. To solve this problem, this paper initially employs manual extraction to precisely define the facial Region of Interest (ROI), expanding the facial area while avoiding rigid regions such as the eyes and mouth to minimize the impact of motion artifacts. Additionally, during the training phase, illumination normalization is employed on video frames with uneven lighting to mitigate noise caused by lighting fluctuations. Finally, this paper introduces a 3D convolutional neural network (CNN) method incorporating an attention mechanism for heart rate detection from facial videos. We optimize the traditional 3D-CNN to capture global features in spatiotemporal data more effectively. The SimAM attention mechanism is introduced to enable the model to precisely focus on and enhance facial ROI feature representations. Following the extraction of rPPG signals, a heart rate estimation network using a bidirectional long short-term memory (BiLSTM) model is employed to derive the heart rate from the signals. The method introduced here is experimentally validated on two publicly available datasets, UBFC-rPPG and PURE. The mean absolute errors were 0.24 bpm and 0.65 bpm, the root mean square errors were 0.63 bpm and 1.30 bpm, and the Pearson correlation coefficients reached 0.99, confirming the method’s reliability. Comparisons of predicted signals with ground truth signals further validated its accuracy.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2025-01-10
DOI
https://doi.org/10.3390/electronics14020269
Citations
3
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
2.02
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Heart Rate Detection from Facial Videos Based on an Attention Mechanism 3D Convolutional Neural Network

Ying Su, Xiujuan Sun, Xiao–Tong Yuan, Hongxue Li et al.
3 citations
Electronics
Non-Invasive Vital Sign Monitoring
2.02
article

Research on Heart Rate Detection from Facial Videos Based on an Attention Mechanism 3D Convolutional Neural Network

Ying Su, Xiujuan Sun, Xiao–Tong Yuan, Hongxue Li, Chuanjiang Wang, Xiankai Hou
article en
3 citations

Abstract

Remote photoplethysmography (rPPG) has attracted growing attention due to its non-contact nature. However, existing non-contact heart rate detection methods are often affected by noise from motion artifacts and changes in lighting, which can lead to a decrease in detection accuracy. To solve this problem, this paper initially employs manual extraction to precisely define the facial Region of Interest (ROI), expanding the facial area while avoiding rigid regions such as the eyes and mouth to minimize the impact of motion artifacts. Additionally, during the training phase, illumination normalization is employed on video frames with uneven lighting to mitigate noise caused by lighting fluctuations. Finally, this paper introduces a 3D convolutional neural network (CNN) method incorporating an attention mechanism for heart rate detection from facial videos. We optimize the traditional 3D-CNN to capture global features in spatiotemporal data more effectively. The SimAM attention mechanism is introduced to enable the model to precisely focus on and enhance facial ROI feature representations. Following the extraction of rPPG signals, a heart rate estimation network using a bidirectional long short-term memory (BiLSTM) model is employed to derive the heart rate from the signals. The method introduced here is experimentally validated on two publicly available datasets, UBFC-rPPG and PURE. The mean absolute errors were 0.24 bpm and 0.65 bpm, the root mean square errors were 0.63 bpm and 1.30 bpm, and the Pearson correlation coefficients reached 0.99, confirming the method’s reliability. Comparisons of predicted signals with ground truth signals further validated its accuracy.

ElectronicsVol. 14(2)
Shandong University of Science and Technology (CN)
Openalex Percentile: Top 16%
Non-Invasive Vital Sign Monitoring
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines