Performance of the fractional step method with various temporal discretization and adaptive time step size schemes for pulsating ventilation

Pulsating ventilation has been drawing extensive attention recently. Computational fluid dynamics (CFD), as a widely used and effective tool for investigating pulsating ventilation, often consumes significant computation time. To identify a suitable numerical scheme for this circumstance, we adopted the standard incremental pressure-correction (SIPC) method with higher-order temporal discretization schemes to simulate indoor airflow. To further improve the simulation efficiency, two adaptive time step size schemes were proposed and used to simulate both long-period and short-period pulsating ventilation conditions. Results showed that the SIPC scheme offers accuracy comparable to the PISO (pressure-implicit with splitting of operators) algorithm while saving about 40% of computation time. Higher-order temporal discretization schemes have minimal impact on the accuracy and stability of the SIPC scheme for simulating pulsating airflow, with the first-order Euler backward implicit scheme showing slightly higher efficiency. Compared to the conventional fixed time step size scheme (fixed scheme), both adaptive time step size schemes significantly reduce computation time with negligible impact on accuracy. The scheme that controls time step size based on a given maximum Courant number (MaxCo scheme) saves about 35% of computation time, while the scheme that combines a given maximum Courant number with the curvature of the inlet velocity-time curve (MaxCo+K scheme) to control time step size saves nearly 30%. Although the MaxCo+K scheme requires about 10% more computation time than the MaxCo scheme, it improved accuracy by approximately 10% by more accurately capturing the inlet velocity boundary condition in the short-period pulsating ventilation simulation.

Authors

Institutions

Publication Details

Journal
Physics of Fluids
Published
2025-01-01
DOI
https://doi.org/10.1063/5.0250564
Citations
2
Primary Topic
Wind and Air Flow Studies
Type
article
Field-Weighted Citation Impact
1.60

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of the fractional step method with various temporal discretization and adaptive time step size schemes for pulsating ventilation

Jiangfeng Hu, Jingzhi Li, Pengzhi Zhou, Haidong Wang et al.
2 citations
Physics of Fluids
Wind and Air Flow Studies
1.60
article

Performance of the fractional step method with various temporal discretization and adaptive time step size schemes for pulsating ventilation

Jiangfeng Hu, Jingzhi Li, Pengzhi Zhou, Haidong Wang, Yuwei Dai
article en
2 citations

Abstract

Pulsating ventilation has been drawing extensive attention recently. Computational fluid dynamics (CFD), as a widely used and effective tool for investigating pulsating ventilation, often consumes significant computation time. To identify a suitable numerical scheme for this circumstance, we adopted the standard incremental pressure-correction (SIPC) method with higher-order temporal discretization schemes to simulate indoor airflow. To further improve the simulation efficiency, two adaptive time step size schemes were proposed and used to simulate both long-period and short-period pulsating ventilation conditions. Results showed that the SIPC scheme offers accuracy comparable to the PISO (pressure-implicit with splitting of operators) algorithm while saving about 40% of computation time. Higher-order temporal discretization schemes have minimal impact on the accuracy and stability of the SIPC scheme for simulating pulsating airflow, with the first-order Euler backward implicit scheme showing slightly higher efficiency. Compared to the conventional fixed time step size scheme (fixed scheme), both adaptive time step size schemes significantly reduce computation time with negligible impact on accuracy. The scheme that controls time step size based on a given maximum Courant number (MaxCo scheme) saves about 35% of computation time, while the scheme that combines a given maximum Courant number with the curvature of the inlet velocity-time curve (MaxCo+K scheme) to control time step size saves nearly 30%. Although the MaxCo+K scheme requires about 10% more computation time than the MaxCo scheme, it improved accuracy by approximately 10% by more accurately capturing the inlet velocity boundary condition in the short-period pulsating ventilation simulation.

Physics of FluidsVol. 37(1)
University of Shanghai for Science and Technology (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 21%
Wind and Air Flow Studies
1.60
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.