Understanding the difference between the nano and micro bubble size distributions generated by a regenerative turbine microbubble generator using ozone

There is a genuine paucity of data concerning the relative significance of the nano and the microbubble size distributions that are collectively generated when operating microbubble generation devices. Accordingly, the current work aimed to address this knowledge gap by measuring the two size distributions generated by a regenerative turbine microbubble generator using ozone and assess the relative significance of the nanobubble fraction. The microbubble fraction was measured with a focus-beam reflectance measurement device and the nanobubble fraction with a nano particle tracking instrument. The latter was calibrated using latex spheres to understand method uncertainty and to optimise the measurement approach. Sauter mean diameters of 217 nm and 37 μm were reported for the nano and microbubble fractions, respectively, with half of the microbubbles being <5000 nm in size. A comparison of the size and number concentrations of the different bubble types revealed that the majority of the gas was contained within the microbubble fraction, and hence, this controlled the overall mass transfer performance of the system. Further, the nanobubbles were observed to be stable for 18 h with little change in their size or number, indicating there was no net transfer of their gaseous contents. Overall, the work revealed that when considering enhancing gas-liquid mass transfer processes with micro-nano bubble generators, the microbubble fraction is key. • First reported study to independently measure the nano and micro ozone bubble sizes formed in a micro-nano bubble generator • The average bubble sizes were 217 nm and 37,000 nm and number concentrations were 2.9 × 10 7 and 2.56 × 10 6 number mL −1 • The majority of mass transfer is associated to the microbubble fraction

Authors

Institutions

Publication Details

Journal
Journal of Water Process Engineering
Published
2025-01-09
DOI
https://doi.org/10.1016/j.jwpe.2025.106963
Citations
7
Primary Topic
Minerals Flotation and Separation Techniques
Type
article
Field-Weighted Citation Impact
5.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Understanding the difference between the nano and micro bubble size distributions generated by a regenerative turbine microbubble generator using ozone

Bruce Jefferson, Adam Brookes, Alexander John, Peter Jarvis et al.
7 citations
Journal of Water Process Engineering
Minerals Flotation and Separation Techniques
5.72
article

Understanding the difference between the nano and micro bubble size distributions generated by a regenerative turbine microbubble generator using ozone

Bruce Jefferson, Adam Brookes, Alexander John, Peter Jarvis, Irene Carra
article en
7 citations

Abstract

There is a genuine paucity of data concerning the relative significance of the nano and the microbubble size distributions that are collectively generated when operating microbubble generation devices. Accordingly, the current work aimed to address this knowledge gap by measuring the two size distributions generated by a regenerative turbine microbubble generator using ozone and assess the relative significance of the nanobubble fraction. The microbubble fraction was measured with a focus-beam reflectance measurement device and the nanobubble fraction with a nano particle tracking instrument. The latter was calibrated using latex spheres to understand method uncertainty and to optimise the measurement approach. Sauter mean diameters of 217 nm and 37 μm were reported for the nano and microbubble fractions, respectively, with half of the microbubbles being <5000 nm in size. A comparison of the size and number concentrations of the different bubble types revealed that the majority of the gas was contained within the microbubble fraction, and hence, this controlled the overall mass transfer performance of the system. Further, the nanobubbles were observed to be stable for 18 h with little change in their size or number, indicating there was no net transfer of their gaseous contents. Overall, the work revealed that when considering enhancing gas-liquid mass transfer processes with micro-nano bubble generators, the microbubble fraction is key. • First reported study to independently measure the nano and micro ozone bubble sizes formed in a micro-nano bubble generator • The average bubble sizes were 217 nm and 37,000 nm and number concentrations were 2.9 × 10 7 and 2.56 × 10 6 number mL −1 • The majority of mass transfer is associated to the microbubble fraction

Journal of Water Process EngineeringVol. 70
Anglian Water Services (United Kingdom) (GB), Cranfield University (GB)
Engineering and Physical Sciences Research Council
Affordable and clean energy
Openalex Percentile: Top 5%
Minerals Flotation and Separation Techniques
5.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.