Analysis of Modular Multilevel Matrix Converter Considering Coupling of Electrical Variables Under Grid-side Asymmetric Faults

The flexible low-frequency AC transmission system (LFAC) is a novel transmission scheme oriented to the efficient consumption of new energy resources. However, the safety operation of LFAC will be threatened under grid-side asymmetric faults. This paper focuses on the analysis of internal dynamic coupling characteristics among electrical variables in M3C under grid-side asymmetric faults with the integration of closed-loop analysis method and the 2-D phasor method. This method can effectively realize the modeling of each electrical variables under asymmetric faults, clearly describe the internal coupling modes, and further reveals the coupling mechanism of internal and external characteristics in M3C. Firstly, the cyclic coupling relationship of electrical variables in M3C based on closed-loop analysis method is introduced; Then, the generation mechanism and coupling characteristics of secondary ripple voltage components and triple harmonic current components is further analyzed. Finally, the correctness of analysis method is verified by Matlab/simulink.

Authors

Institutions

Publication Details

Published
2024-11-06
DOI
https://doi.org/10.1109/pepsc63375.2024.10823423
Citations
1
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Modular Multilevel Matrix Converter Considering Coupling of Electrical Variables Under Grid-side Asymmetric Faults

Xiaojun Ni, Jing Li, Lianhui Ning, Boyang Zhao et al.
1 citations
HVDC Systems and Fault Protection
0.21
article

Analysis of Modular Multilevel Matrix Converter Considering Coupling of Electrical Variables Under Grid-side Asymmetric Faults

Xiaojun Ni, Jing Li, Lianhui Ning, Boyang Zhao, Peng Qiu, Yi Lu
article en
1 citations

Abstract

The flexible low-frequency AC transmission system (LFAC) is a novel transmission scheme oriented to the efficient consumption of new energy resources. However, the safety operation of LFAC will be threatened under grid-side asymmetric faults. This paper focuses on the analysis of internal dynamic coupling characteristics among electrical variables in M3C under grid-side asymmetric faults with the integration of closed-loop analysis method and the 2-D phasor method. This method can effectively realize the modeling of each electrical variables under asymmetric faults, clearly describe the internal coupling modes, and further reveals the coupling mechanism of internal and external characteristics in M3C. Firstly, the cyclic coupling relationship of electrical variables in M3C based on closed-loop analysis method is introduced; Then, the generation mechanism and coupling characteristics of secondary ripple voltage components and triple harmonic current components is further analyzed. Finally, the correctness of analysis method is verified by Matlab/simulink.

Shanghai Electric (China) (CN), Xi'an Jiaotong University (CN)
Openalex Percentile: Top 44%
HVDC Systems and Fault Protection
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.