Development of a Semiquantitative Barcode Readout Approach for Paper-Based Analytical Devices (PADs) for Enzymatic H<sub>2</sub>O<sub>2</sub> and Glucose Detection

The integration of barcode technology with smartphones on paper-based analytical devices (PADs) presents a promising approach to bridging manual detection with digital interpretation and data storage. However, previous studies of 1D barcode approaches have been limited to providing only a "yes/no" response for analyte detection. Herein, a method of using barcode readout for semiquantitative signal detection on PADs has been achieved through the integration of barcode technology with a distance-based measurement concept on PADs. To demonstrate the feasibility of this concept, a PAD fabrication strategy incorporating barcodes was explored, using the enzymatic reaction between horseradish peroxidase (HRP), 3,3'-diaminobenzidine (DAB), and H<sub>2</sub>O<sub>2</sub> as a model system. The enzyme-catalyzed polymerization of DAB to polyDAB in the presence of hydrogen peroxide results in the appearance of color observable by the naked eye inside a paperfluidic channel, with the color-changed length depending on the H<sub>2</sub>O<sub>2</sub> concentration. At the same time, the barcode pattern displayed as a result of this distance-based color evolution overlaid with a paper-based barcode layer can be read using a smartphone application. Parameters affecting the signal readout performance were studied. The developed device can be used to detect H<sub>2</sub>O<sub>2</sub> concentrations in the range of 0.25 to 10 mM within 90 min with 79.6% of barcode signals correctly readable. Additionally, results from different smartphone models showed a consistent reading performance (78.4-79.6%). Finally, the quantification of glucose levels in artificial urine samples was demonstrated. This developed PAD signaling strategy offers end-users more simplicity and can be used as a standalone device or in conjunction with other digital devices.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-01-10
DOI
https://doi.org/10.1021/acs.analchem.4c04113
Citations
10
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
6.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Semiquantitative Barcode Readout Approach for Paper-Based Analytical Devices (PADs) for Enzymatic H2O2 and Glucose Detection

Yuki Hiruta, Daniel Citterio, Yanawut Manmana, Shuma Kinugasa
10 citations
Analytical Chemistry
Biosensors and Analytical Detection
6.74
article

Development of a Semiquantitative Barcode Readout Approach for Paper-Based Analytical Devices (PADs) for Enzymatic H2O2 and Glucose Detection

Yuki Hiruta, Daniel Citterio, Yanawut Manmana, Shuma Kinugasa
article en
10 citations

Abstract

The integration of barcode technology with smartphones on paper-based analytical devices (PADs) presents a promising approach to bridging manual detection with digital interpretation and data storage. However, previous studies of 1D barcode approaches have been limited to providing only a "yes/no" response for analyte detection. Herein, a method of using barcode readout for semiquantitative signal detection on PADs has been achieved through the integration of barcode technology with a distance-based measurement concept on PADs. To demonstrate the feasibility of this concept, a PAD fabrication strategy incorporating barcodes was explored, using the enzymatic reaction between horseradish peroxidase (HRP), 3,3'-diaminobenzidine (DAB), and H<sub>2</sub>O<sub>2</sub> as a model system. The enzyme-catalyzed polymerization of DAB to polyDAB in the presence of hydrogen peroxide results in the appearance of color observable by the naked eye inside a paperfluidic channel, with the color-changed length depending on the H<sub>2</sub>O<sub>2</sub> concentration. At the same time, the barcode pattern displayed as a result of this distance-based color evolution overlaid with a paper-based barcode layer can be read using a smartphone application. Parameters affecting the signal readout performance were studied. The developed device can be used to detect H<sub>2</sub>O<sub>2</sub> concentrations in the range of 0.25 to 10 mM within 90 min with 79.6% of barcode signals correctly readable. Additionally, results from different smartphone models showed a consistent reading performance (78.4-79.6%). Finally, the quantification of glucose levels in artificial urine samples was demonstrated. This developed PAD signaling strategy offers end-users more simplicity and can be used as a standalone device or in conjunction with other digital devices.

Analytical ChemistryVol. 97(3)
Keio University (JP)
Japan Society for the Promotion of Science
Openalex Percentile: Top 3%
Biosensors and Analytical Detection
6.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.