Decoupling pulse tube vibrations from a dry dilution refrigerator at milli-Kelvin temperatures

Abstract With the rising adoption of dry dilution refrigerators across scientific and industrial domains, there has been a pressing demand for highly efficient vibration decoupling systems capable of operation at cryogenic temperatures in order to achieve the low vibration levels required for operation of sensitive equipment like cryogenic detectors or quantum devices. As part of the NUCLEUS experiment, a cryogenic spring pendulum has been engineered to effectively isolate pulse tube vibrations by establishing an autonomous frame of reference for the experimental volume, while sustaining temperatures below 10 mK. Attaining attenuation of up to two orders of magnitude within the region of interest of the NUCLEUS cryogenic detectors, we achieved displacement RMS values in the order of 1 nm in the axial direction and 100 pm radially, thereby reducing vibrations below typical environmental levels. Our successful detector operation across multiple cooldown cycles demonstrated negligible sensitivity to pulse tube induced vibrations, culminating in the achievement of an ultra-low (6.22 ± 0.07) eV baseline resolution on a gram-scale CaWO 4 cryogenic calorimeter during continuous pulse tube operation over the course of several weeks.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2025-05-01
DOI
https://doi.org/10.1088/1748-0221/20/05/p05022
Citations
1
Primary Topic
Quantum, superfluid, helium dynamics
Type
article
Field-Weighted Citation Impact
1.25
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Decoupling pulse tube vibrations from a dry dilution refrigerator at milli-Kelvin temperatures

F. Cappella, D. Lhuillier, E. Bossio, C. Tomei et al.
1 citations
Journal of Instrumentation
Quantum, superfluid, helium dynamics
1.25
article

Decoupling pulse tube vibrations from a dry dilution refrigerator at milli-Kelvin temperatures

F. Cappella, D. Lhuillier, E. Bossio, C. Tomei, T. Ortmann, A Cruciani, F. Petricca, S. Fichtinger, B. Mauri, A. Kinast, L. Pattavina, M. Giammei, A. Doblhammer, C. Schwertner, M. Kaznacheeva, M Vignati, A. Erhart, F. Reindl, B. Arnold, A. Mazzolari, A. Langenkämper, S. Schönert, M. Vivier, H. Neyrial, J. Burkhart, Abhijit Garai, Robert Martin, G. del Castello, L. Peters, H. Abele, C Nones, H. Kluck, W. Potzel, M. Atzori Corona, L. Canonica, C. Goupy, A. Bento, M. Tamisari, L. Stodolsky, S. Dorer, G. Angloher, A. Wex, V. M. Ghete, L. Scola, E. Jericha, G. Soum-Sidikov, Du Toit Strauss, N Casali, M. Romagnoni, J. Schieck, F. Pröbst, J. Rothe, F. Jeanneau, M. Friedl, R. Cerulli, T. Lasserre, D. Hauff, V. Wagner, M. del Gallo Roccagiovine, F. Pucci, N. Schermer, M Mancuso, E. Mazzucato, R. Thalmeier, L Oberauer, M. Cappelli
article en
1 citations

Abstract

Abstract With the rising adoption of dry dilution refrigerators across scientific and industrial domains, there has been a pressing demand for highly efficient vibration decoupling systems capable of operation at cryogenic temperatures in order to achieve the low vibration levels required for operation of sensitive equipment like cryogenic detectors or quantum devices. As part of the NUCLEUS experiment, a cryogenic spring pendulum has been engineered to effectively isolate pulse tube vibrations by establishing an autonomous frame of reference for the experimental volume, while sustaining temperatures below 10 mK. Attaining attenuation of up to two orders of magnitude within the region of interest of the NUCLEUS cryogenic detectors, we achieved displacement RMS values in the order of 1 nm in the axial direction and 100 pm radially, thereby reducing vibrations below typical environmental levels. Our successful detector operation across multiple cooldown cycles demonstrated negligible sensitivity to pulse tube induced vibrations, culminating in the achievement of an ultra-low (6.22 ± 0.07) eV baseline resolution on a gram-scale CaWO 4 cryogenic calorimeter during continuous pulse tube operation over the course of several weeks.

Journal of InstrumentationVol. 20(05)
Université Paris Cité (FR), Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR), Laboratoire AstroParticule et Cosmologie (FR), CEA Paris-Saclay (FR), Institut de Recherche sur les Lois Fondamentales de l'Univers (FR)
Affordable and clean energy
Openalex Percentile: Top 25%
Quantum, superfluid, helium dynamics
1.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.