The National Early Warning Score 2 versus the New-Poisoning Mortality Score System for Predicting Clinical Outcomes After Acute Aluminum Phosphide Poisoning

Acute aluminum phosphide (AlP) poisoning is one of the leading causes of suicide, particularly in the developing world. In cases of scarce and/or high-cost resources, it is advisable to prioritize critically ill patients who will benefit from available resources and improve their prognosis. Despite numerous scores, a dependable, easy-to-use, and quick approach to assessing the degree of poisoning is lacking. This study is designed to compare the prognostic performance of the National Early Warning Score 2 (NEWS2) versus the new-poisoning mortality score system (new-PMS) for predicting the clinical outcomes, including in-hospital mortality, vasopressor use, and mechanical ventilation placement after acute AlP poisoning. This study was a retrospective observational study that included patients with acute AlP poisoning with retrieving the required data from the patients' medical records. A total of 90 acutely AlP-intoxicated patients were enrolled in the study. The in-hospital mortality rate was 42.2%. Additionally, in-hospital mortality, vasopressor use, and mechanical ventilation placement were significantly higher in patients with higher NEWS2 and new-PMS scores. The new-PMS showed excellent prognostic performance, particularly in-hospital mortality prediction; however, NEWS2 demonstrated a more helpful predictive performance compared to the new-PMS particularly for the need for mechanical ventilation and in-hospital mortality, with an area under the curve of 0.991 versus 0.851 and 0.949 versus 0.874, respectively. We concluded that NEWS2 and new-PMS are simple, easily calculated, and lab-independent scoring systems. The NEWS2 is a more effective tracking and triggering tool than the new-PMS in the evaluation of AlP acutely intoxicated patients.

Authors

Institutions

Publication Details

Journal
Toxicology Research
Published
2024-12-27
DOI
https://doi.org/10.1093/toxres/tfae230
Citations
1
Primary Topic
Poisoning and overdose treatments
Type
article
Field-Weighted Citation Impact
0.69
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The National Early Warning Score 2 versus the New-Poisoning Mortality Score System for Predicting Clinical Outcomes After Acute Aluminum Phosphide Poisoning

Ola Elsayed Nafea, Walaa G. Abdelhamid, Fatma Ibrahim
1 citations
Toxicology Research
Poisoning and overdose treatments
0.69
article

The National Early Warning Score 2 versus the New-Poisoning Mortality Score System for Predicting Clinical Outcomes After Acute Aluminum Phosphide Poisoning

Ola Elsayed Nafea, Walaa G. Abdelhamid, Fatma Ibrahim
article en
1 citations

Abstract

Acute aluminum phosphide (AlP) poisoning is one of the leading causes of suicide, particularly in the developing world. In cases of scarce and/or high-cost resources, it is advisable to prioritize critically ill patients who will benefit from available resources and improve their prognosis. Despite numerous scores, a dependable, easy-to-use, and quick approach to assessing the degree of poisoning is lacking. This study is designed to compare the prognostic performance of the National Early Warning Score 2 (NEWS2) versus the new-poisoning mortality score system (new-PMS) for predicting the clinical outcomes, including in-hospital mortality, vasopressor use, and mechanical ventilation placement after acute AlP poisoning. This study was a retrospective observational study that included patients with acute AlP poisoning with retrieving the required data from the patients' medical records. A total of 90 acutely AlP-intoxicated patients were enrolled in the study. The in-hospital mortality rate was 42.2%. Additionally, in-hospital mortality, vasopressor use, and mechanical ventilation placement were significantly higher in patients with higher NEWS2 and new-PMS scores. The new-PMS showed excellent prognostic performance, particularly in-hospital mortality prediction; however, NEWS2 demonstrated a more helpful predictive performance compared to the new-PMS particularly for the need for mechanical ventilation and in-hospital mortality, with an area under the curve of 0.991 versus 0.851 and 0.949 versus 0.874, respectively. We concluded that NEWS2 and new-PMS are simple, easily calculated, and lab-independent scoring systems. The NEWS2 is a more effective tracking and triggering tool than the new-PMS in the evaluation of AlP acutely intoxicated patients.

Toxicology ResearchVol. 14(1)
Ain Shams University (EG), Zagazig University (EG)
Good health and well-being
Openalex Percentile: Top 23%
Poisoning and overdose treatments
0.69
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.