Update of the BIPM comparison BIPM.RI(II)-K1.Mn-54 of activity measurements of the radionuclide <sup>54</sup>Mn to include the 2024 result of the POLATOM (Poland)

Main text Since 1976, 17 laboratories have submitted 43 samples of 54 Mn to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM), with comparison identifier BIPM.RI(II)-K1.Mn-54. Recently, the POLATOM (Poland) participated in the comparison and the key comparison reference value (KCRV) has been updated. The degrees of equivalence between each equivalent activity measured in the SIR and the updated KCRV have been calculated and the results are given in the form of a table. A graphical representation is also given. To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/ . The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

Authors

Institutions

Publication Details

Journal
Metrologia
Published
2025-01-01
DOI
https://doi.org/10.1088/0026-1394/62/1a/06001
Primary Topic
Radioactive Decay and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Update of the BIPM comparison BIPM.RI(II)-K1.Mn-54 of activity measurements of the radionuclide 54Mn to include the 2024 result of the POLATOM (Poland)

Paweł Saganowski, Z. Tymiński, Edyta Lech, J. Marganiec et al.
Metrologia
Radioactive Decay and Measurement Techniques
article

Update of the BIPM comparison BIPM.RI(II)-K1.Mn-54 of activity measurements of the radionuclide 54Mn to include the 2024 result of the POLATOM (Poland)

Paweł Saganowski, Z. Tymiński, Edyta Lech, J. Marganiec, Romain Coulon, S Courte, Manuel Nonis, Vincent Gressier, C Michotte
article en

Abstract

Main text Since 1976, 17 laboratories have submitted 43 samples of 54 Mn to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM), with comparison identifier BIPM.RI(II)-K1.Mn-54. Recently, the POLATOM (Poland) participated in the comparison and the key comparison reference value (KCRV) has been updated. The degrees of equivalence between each equivalent activity measured in the SIR and the updated KCRV have been calculated and the results are given in the form of a table. A graphical representation is also given. To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/ . The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

MetrologiaVol. 62(1A)
National Centre for Nuclear Research (PL), Bureau international des poids et mesures (FR)
Partnerships for the goals
Openalex Percentile: Top 99%
Radioactive Decay and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.