Improved Precision and Sensitivity: Refinement of a Homebrew Simoa Assay for Detecting pTau181 in Plasma and Serum

Abstract Background Plasma tau phosphorylated at Threonine181 (pTau181) has been extensively studied as an accessible biomarker of amyloid pathology and is compared in various studies with other pTau epitopes. ADx has developed a Quanterix Homebrew Simoa assay using a highly pTau181 specific capture mAb (ADx252) and an N‐terminal tau detector ADx204 demonstrating high clinical performance (Janelidze et al ., 2023; Ashton et al ., 2022; Bayoumy et al ., 2021). Nevertheless, measuring pTau181 in samples from young adults or serum that have lower levels remains challenging due to limited sensitivity and precision in the low calibrator range. This work describes an updated Homebrew assay for detection of pTau181 in human plasma and serum with increased precision and sensitivity compared to the previously published ADx pTau181 Simoa assay. Method The ADx pTau181 assay was updated using re‐engineered formats of ADx252 (RD‐070) and ADx204 (RD‐073). Antibody conjugation to beads was optimized by C‐terminal incorporation of a tag to enhance antibody conjugation efficiency and robustness. The assay was further optimized using alternative diluents resulting in a linear curve over the full calibrator range. The clinical performance of the assay format was compared to the previous pTau181 assay version using plasma from 50 AD patients (defined by CSF biomarker profile) and 50 cognitively healthy donors from the Dutch Brain Research Registry (Hersenonderzoek.nl). Paired plasma and serum from a prospective collection of healthy donors (n = 50) were also analyzed using the optimized pTau181 assay. Result The optimized assay showed a higher AUC of 0.96 (95% CI 0.92‐0.99) compared to 0.88 (95% CI 0.82 – 0.95) for the previous version (ΔAUC = 0.08, DeLong’s p = 0.047). Furthermore, our optimized assay was able to measure serum pTau 181, exhibiting a strong correlation of the analyte between plasma and serum and with pTau217 levels. Additionally, precision and sensitivity were improved (no vs. 18 plasma samples with CV%>20 on duplicate measurements; mean plasma sample S/N increased from 4.3 to 9.8). Conclusion Our study illustrates the successful development of an optimized Homebrew pTau181 assay, with enhanced analytical and clinical performance achieved by an improved sensitivity and precision at measuring pTau 181 in plasma and serum samples.

Authors

Institutions

Publication Details

Journal
Alzheimer s & Dementia
Published
2024-12-01
DOI
https://doi.org/10.1002/alz.095453
Primary Topic
Computational Drug Discovery Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improved Precision and Sensitivity: Refinement of a Homebrew Simoa Assay for Detecting pTau181 in Plasma and Serum

Sherif Bayoumy, Wiesje M. van der Flier, Erik Stoops, Jeroen Vanbrabant et al.
Alzheimer s & Dementia
Computational Drug Discovery Methods
article

Improved Precision and Sensitivity: Refinement of a Homebrew Simoa Assay for Detecting pTau181 in Plasma and Serum

Sherif Bayoumy, Wiesje M. van der Flier, Erik Stoops, Jeroen Vanbrabant, Daniel Antwi‐Berko, Inge M.W. Verberk, Charlotte Elisabeth Teunissen
article en

Abstract

Abstract Background Plasma tau phosphorylated at Threonine181 (pTau181) has been extensively studied as an accessible biomarker of amyloid pathology and is compared in various studies with other pTau epitopes. ADx has developed a Quanterix Homebrew Simoa assay using a highly pTau181 specific capture mAb (ADx252) and an N‐terminal tau detector ADx204 demonstrating high clinical performance (Janelidze et al ., 2023; Ashton et al ., 2022; Bayoumy et al ., 2021). Nevertheless, measuring pTau181 in samples from young adults or serum that have lower levels remains challenging due to limited sensitivity and precision in the low calibrator range. This work describes an updated Homebrew assay for detection of pTau181 in human plasma and serum with increased precision and sensitivity compared to the previously published ADx pTau181 Simoa assay. Method The ADx pTau181 assay was updated using re‐engineered formats of ADx252 (RD‐070) and ADx204 (RD‐073). Antibody conjugation to beads was optimized by C‐terminal incorporation of a tag to enhance antibody conjugation efficiency and robustness. The assay was further optimized using alternative diluents resulting in a linear curve over the full calibrator range. The clinical performance of the assay format was compared to the previous pTau181 assay version using plasma from 50 AD patients (defined by CSF biomarker profile) and 50 cognitively healthy donors from the Dutch Brain Research Registry (Hersenonderzoek.nl). Paired plasma and serum from a prospective collection of healthy donors (n = 50) were also analyzed using the optimized pTau181 assay. Result The optimized assay showed a higher AUC of 0.96 (95% CI 0.92‐0.99) compared to 0.88 (95% CI 0.82 – 0.95) for the previous version (ΔAUC = 0.08, DeLong’s p = 0.047). Furthermore, our optimized assay was able to measure serum pTau 181, exhibiting a strong correlation of the analyte between plasma and serum and with pTau217 levels. Additionally, precision and sensitivity were improved (no vs. 18 plasma samples with CV%>20 on duplicate measurements; mean plasma sample S/N increased from 4.3 to 9.8). Conclusion Our study illustrates the successful development of an optimized Homebrew pTau181 assay, with enhanced analytical and clinical performance achieved by an improved sensitivity and precision at measuring pTau 181 in plasma and serum samples.

Alzheimer s & DementiaVol. 20(S8)
Ablynx (Belgium) (BE), Amsterdam Neuroscience (NL), Amsterdam University Medical Centers (NL), ADx NeuroSciences, Vrije Universiteit Amsterdam (NL)
Openalex Percentile: Top 70%
Computational Drug Discovery Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.