Quantitative Analysis of Choroid Plexus Enlargement in Alzheimer’s Dementia: A Study of Automated Volumetric Technique

Abstract Background Choroid plexus enlargement is implicated in the exacerbation of cognitive impairments characteristic of Alzheimer’s dementia (AD). Manual volumetric assessment by radiologists, while accurate, is impractical for large‐scale application due to its resource‐intensive nature. We examine the use of automated brain volumetry software as an efficient and cost‐effective alternative for quantifying choroid plexus volume. Method We collected 3D T1 brain MRI images from 293 patients aged between 44 and 91, with a median age of 73, at Konkuk University Hospital (n = 95), Asan Medical Center (n = 99), and the Alzheimer’s Disease Neuroimaging Initiative (ADNI) (n = 99). The study comprised 76 normal control (NC), 89 mild cognitive impairment (MCI), and 128 AD cases, with a female majority of 58.4%. Using VUNO‐Med DeepBrain software, we obtained choroid plexus segmentation masks and volumes from both radiologists and neural networks trained with deep learning. All choroid plexus volumes were normalized by intracranial volume (ICV) multiplied by 1000. Additionally, to assess DeepBrain’s accuracy, we calculated the Intraclass Correlation Coefficient (ICC(2, k)) between the manually labeled volumes and those labeled by DeepBrain. Result The median choroid plexus volumes measured by radiologists were 1.328 for NC, 1.354 for MCI, and 1.495 for AD. In contrast, measurements by DeepBrain were 1.163 (NC), 1.284 (MCI), and 1.428 (AD). A one‐way ANOVA analysis (NC vs. MCI vs. AD) revealed that DeepBrain‐based measurements (p < 0.001) may be more significant than manual measurements (p = 0.17) in elucidating the relationship between choroid plexus enlargement and cognitive impairments in AD. Additionally, the Intraclass Correlation Coefficient (ICC(2, k)) between manual and DeepBrain volumes indicated a moderate correlation with a score of 0.69 (p < 0.001). Conclusion Our results suggest that automated brain volumetry is a reliable method for assessing choroid plexus volume, correlating with the cognitive impairment continuum in AD. Its implementation could significantly streamline the diagnostic process, offering a scalable and objective approach for clinicians and researchers.

Authors

Institutions

Publication Details

Journal
Alzheimer s & Dementia
Published
2024-12-01
DOI
https://doi.org/10.1002/alz.093792
Primary Topic
Retinal Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative Analysis of Choroid Plexus Enlargement in Alzheimer’s Dementia: A Study of Automated Volumetric Technique

H. Cho, Chong Hyun Suh, Yeha Lee, Won‐Jin Moon et al.
Alzheimer s & Dementia
Retinal Imaging and Analysis
article

Quantitative Analysis of Choroid Plexus Enlargement in Alzheimer’s Dementia: A Study of Automated Volumetric Technique

H. Cho, Chong Hyun Suh, Yeha Lee, Won‐Jin Moon, Jinyoung Kim, Seung Hyun Lee, Donghee Kim, Sang Joon Kim, Wooseok Jung
article en

Abstract

Abstract Background Choroid plexus enlargement is implicated in the exacerbation of cognitive impairments characteristic of Alzheimer’s dementia (AD). Manual volumetric assessment by radiologists, while accurate, is impractical for large‐scale application due to its resource‐intensive nature. We examine the use of automated brain volumetry software as an efficient and cost‐effective alternative for quantifying choroid plexus volume. Method We collected 3D T1 brain MRI images from 293 patients aged between 44 and 91, with a median age of 73, at Konkuk University Hospital (n = 95), Asan Medical Center (n = 99), and the Alzheimer’s Disease Neuroimaging Initiative (ADNI) (n = 99). The study comprised 76 normal control (NC), 89 mild cognitive impairment (MCI), and 128 AD cases, with a female majority of 58.4%. Using VUNO‐Med DeepBrain software, we obtained choroid plexus segmentation masks and volumes from both radiologists and neural networks trained with deep learning. All choroid plexus volumes were normalized by intracranial volume (ICV) multiplied by 1000. Additionally, to assess DeepBrain’s accuracy, we calculated the Intraclass Correlation Coefficient (ICC(2, k)) between the manually labeled volumes and those labeled by DeepBrain. Result The median choroid plexus volumes measured by radiologists were 1.328 for NC, 1.354 for MCI, and 1.495 for AD. In contrast, measurements by DeepBrain were 1.163 (NC), 1.284 (MCI), and 1.428 (AD). A one‐way ANOVA analysis (NC vs. MCI vs. AD) revealed that DeepBrain‐based measurements (p < 0.001) may be more significant than manual measurements (p = 0.17) in elucidating the relationship between choroid plexus enlargement and cognitive impairments in AD. Additionally, the Intraclass Correlation Coefficient (ICC(2, k)) between manual and DeepBrain volumes indicated a moderate correlation with a score of 0.69 (p < 0.001). Conclusion Our results suggest that automated brain volumetry is a reliable method for assessing choroid plexus volume, correlating with the cognitive impairment continuum in AD. Its implementation could significantly streamline the diagnostic process, offering a scalable and objective approach for clinicians and researchers.

Alzheimer s & DementiaVol. 20(S9)
Ulsan College (KR), Konkuk University (KR), Asan Medical Center (KR), University of Ulsan (KR)
Openalex Percentile: Top 58%
Retinal Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.