Independently validating a novel modification to the Single Molecule Array technology in a pilot Alzheimer’s disease cohort

Abstract Background A novel improvement to Quanterix Corporation Single molecule array (Simoa) SR‐X instrument has been shown to offer up to 100‐fold increased sensitivity compared with standard Simoa HD‐X and SR‐X instruments. We independently validated this increased sensitivity using the Simoa interleukin 17A (IL17A) assay. Method IL17A was measured in 32 paired Alzheimer’s disease (AD; n = 13) and control (CTRL; n = 19) serum and cerebrospinal fluid (CSF) samples. Mean IL17A concentrations were compared in both biofluids measured using four Simoa instruments ‐ one HD‐X instrument and three SR‐X instruments modified to improve the efficiency of reading beads. Result HD‐X quantified IL17A in 0% of CSF samples and 37.5% of serum samples, with mean serum IL17A concentrations of 0.126pg/mL in AD and 0.228pg/mL in CTRLs. In contrast, the modified SR‐X instruments A, B and C quantified CSF IL17A in 84.4%, 96.9% and 96.9% of CSF samples, respectively, with mean AD concentrations of 2.92fg/mL, 5.95fg/mL and 7.25fg/mL, respectively, and mean CTRL concentrations of 3.60fg/mL, 4.75fg/mL and 9.02fg/mL, respectively. Furthermore, the modified SR‐X instruments A, B and C all quantified IL17A in 100% of serum samples, with mean serum AD concentrations of 0.145pg/mL, 0.285pg/mL, and 0.249pg/mL, respectively, and mean CTRL concentrations of 0.300pg/mL, 0.406pg/mL and 0.362pg/mL, respectively. There were no statistically significant intra‐instrument differences between AD compared with CTRLs. All three modified SR‐X serum concentrations showed a strong positive statistically significant correlation with HD‐X serum concentrations. All three modified SR‐X serum concentrations also showed a strong positive statistically significant correlation with one another. Finally, all three modified SR‐X instruments showed no correlation between serum and CSF concentrations, in line with previous literature. Conclusion Increasing the bead reading efficiency of the SR‐X exhibits increased sensitivity compared with the standard Simoa HD‐X instrument, allowing the quantification of IL17A in CSF and a greater yield of serum samples.

Authors

Institutions

Publication Details

Journal
Alzheimer s & Dementia
Published
2024-12-01
DOI
https://doi.org/10.1002/alz.095520
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Independently validating a novel modification to the Single Molecule Array technology in a pilot Alzheimer’s disease cohort

David C. Duffy, S. Fernandes, Amanda Heslegrave, Cheuk W. Kan et al.
Alzheimer s & Dementia
Advanced biosensing and bioanalysis techniques
article

Independently validating a novel modification to the Single Molecule Array technology in a pilot Alzheimer’s disease cohort

David C. Duffy, S. Fernandes, Amanda Heslegrave, Cheuk W. Kan, Henrik Zetterberg, David M. Rissin, Deborah O T Alawode
article en

Abstract

Abstract Background A novel improvement to Quanterix Corporation Single molecule array (Simoa) SR‐X instrument has been shown to offer up to 100‐fold increased sensitivity compared with standard Simoa HD‐X and SR‐X instruments. We independently validated this increased sensitivity using the Simoa interleukin 17A (IL17A) assay. Method IL17A was measured in 32 paired Alzheimer’s disease (AD; n = 13) and control (CTRL; n = 19) serum and cerebrospinal fluid (CSF) samples. Mean IL17A concentrations were compared in both biofluids measured using four Simoa instruments ‐ one HD‐X instrument and three SR‐X instruments modified to improve the efficiency of reading beads. Result HD‐X quantified IL17A in 0% of CSF samples and 37.5% of serum samples, with mean serum IL17A concentrations of 0.126pg/mL in AD and 0.228pg/mL in CTRLs. In contrast, the modified SR‐X instruments A, B and C quantified CSF IL17A in 84.4%, 96.9% and 96.9% of CSF samples, respectively, with mean AD concentrations of 2.92fg/mL, 5.95fg/mL and 7.25fg/mL, respectively, and mean CTRL concentrations of 3.60fg/mL, 4.75fg/mL and 9.02fg/mL, respectively. Furthermore, the modified SR‐X instruments A, B and C all quantified IL17A in 100% of serum samples, with mean serum AD concentrations of 0.145pg/mL, 0.285pg/mL, and 0.249pg/mL, respectively, and mean CTRL concentrations of 0.300pg/mL, 0.406pg/mL and 0.362pg/mL, respectively. There were no statistically significant intra‐instrument differences between AD compared with CTRLs. All three modified SR‐X serum concentrations showed a strong positive statistically significant correlation with HD‐X serum concentrations. All three modified SR‐X serum concentrations also showed a strong positive statistically significant correlation with one another. Finally, all three modified SR‐X instruments showed no correlation between serum and CSF concentrations, in line with previous literature. Conclusion Increasing the bead reading efficiency of the SR‐X exhibits increased sensitivity compared with the standard Simoa HD‐X instrument, allowing the quantification of IL17A in CSF and a greater yield of serum samples.

Alzheimer s & DementiaVol. 20(S8)
Quanterix (United States) (US), UK Dementia Research Institute (GB), National Hospital for Neurology and Neurosurgery (GB), University College London (GB), University of Gothenburg (SE)
Quality Education
Openalex Percentile: Top 78%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.