Myelin water imaging with clinically feasible scan time: the accelerated BMC‐mcDESPOT (aBMC‐mcDESPOT) method

Abstract Background In 2016, we introduced the Bayesian Monte Carlo analysis of multicomponent‐driven equilibrium observation of T1 and T2 (BMC‐mcDESPOT) MRI method for myelin water fraction (MWF) mapping, a surrogate of myelin content. While BMC‐mcDESPOT has been extensively applied to study brain aging, dementias, and risk factors influencing myelination, it still requires a lengthy acquisition time (∼17 min) which hampers its integration in clinical studies and trials. In this study, we aim to accelerate the BMC‐mcDESPOT method for whole brain, high‐resolution, MWF mapping within clinically feasible scan time of ∼6 min. Method Data Acquisition Reference data (ref‐BMC, no‐acceleration): Two subjects underwent the BMC‐mcDESPOT protocol consisting of SPGR and bSSFP images at 10 different FAs. For assessing reproducibility, three sets of fully‐sampled datasets were collected without any under‐sampling (total acquisition time = 17 min). Compressed sensing acceleration (cs‐BMC): Three sets of accelerated scans were acquired using compressed sensing (CS) with an acceleration factor of ∼2 (9 min) (Figure 1(a)). Image domain acceleration (du‐BMC): The undersampling in the data domain was retrospectively performed on the bSSFP images by selecting only 2 optimal images instead of the full 10 images (12 min) (Figure 1(b)). Combined accelerations (aBMC): The above two acceleration methods were combined and resulted in an acquisition time of ∼6min. (Figure 1(c)) Data Processing We estimated MWF maps from the different undersampling methods described above. The accuracy was evaluated between the MWF from the reference and those from each undersampled dataset. The reproducibility was measured with the coefficient of variations (CoV) across different measurements for each sampling method. We also performed Bland‐Altman analysis to quantify bias and limits of agreement (LOA). Result Figure 2 shows a representative slice of MWF estimates from different sampling methods. The different acceleration methods showed similar regional patterns, with relatively low errors (du‐BMC/cs‐BMC/aBMC = 10.8/9.8/13.7%) and CoV (ref‐BMC/du‐BMC/cs‐BMC/aBMC = 9.0/14.3/10.7/15.3%). While a slight bias in the derived MWF values was observed (Fig.3), the LOA for aBMC was under 5% in white matter. Conclusion aBMC‐mcDESPOT is a practical MRI method for accurate determination of MWF within 6 min, offering unique opportunities to further integrate myelin imaging in clinical studies and trials.

Authors

Institutions

Publication Details

Journal
Alzheimer s & Dementia
Published
2024-12-01
DOI
https://doi.org/10.1002/alz.093655
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Myelin water imaging with clinically feasible scan time: the accelerated BMC‐mcDESPOT (aBMC‐mcDESPOT) method

John P Laporte, Mustapha Bouhrara, Zhaoyuan Gong, Mary E Faulkner et al.
Alzheimer s & Dementia
Advanced MRI Techniques and Applications
article

Myelin water imaging with clinically feasible scan time: the accelerated BMC‐mcDESPOT (aBMC‐mcDESPOT) method

John P Laporte, Mustapha Bouhrara, Zhaoyuan Gong, Mary E Faulkner, Jonghyun Bae, Alex Guo
article en

Abstract

Abstract Background In 2016, we introduced the Bayesian Monte Carlo analysis of multicomponent‐driven equilibrium observation of T1 and T2 (BMC‐mcDESPOT) MRI method for myelin water fraction (MWF) mapping, a surrogate of myelin content. While BMC‐mcDESPOT has been extensively applied to study brain aging, dementias, and risk factors influencing myelination, it still requires a lengthy acquisition time (∼17 min) which hampers its integration in clinical studies and trials. In this study, we aim to accelerate the BMC‐mcDESPOT method for whole brain, high‐resolution, MWF mapping within clinically feasible scan time of ∼6 min. Method Data Acquisition Reference data (ref‐BMC, no‐acceleration): Two subjects underwent the BMC‐mcDESPOT protocol consisting of SPGR and bSSFP images at 10 different FAs. For assessing reproducibility, three sets of fully‐sampled datasets were collected without any under‐sampling (total acquisition time = 17 min). Compressed sensing acceleration (cs‐BMC): Three sets of accelerated scans were acquired using compressed sensing (CS) with an acceleration factor of ∼2 (9 min) (Figure 1(a)). Image domain acceleration (du‐BMC): The undersampling in the data domain was retrospectively performed on the bSSFP images by selecting only 2 optimal images instead of the full 10 images (12 min) (Figure 1(b)). Combined accelerations (aBMC): The above two acceleration methods were combined and resulted in an acquisition time of ∼6min. (Figure 1(c)) Data Processing We estimated MWF maps from the different undersampling methods described above. The accuracy was evaluated between the MWF from the reference and those from each undersampled dataset. The reproducibility was measured with the coefficient of variations (CoV) across different measurements for each sampling method. We also performed Bland‐Altman analysis to quantify bias and limits of agreement (LOA). Result Figure 2 shows a representative slice of MWF estimates from different sampling methods. The different acceleration methods showed similar regional patterns, with relatively low errors (du‐BMC/cs‐BMC/aBMC = 10.8/9.8/13.7%) and CoV (ref‐BMC/du‐BMC/cs‐BMC/aBMC = 9.0/14.3/10.7/15.3%). While a slight bias in the derived MWF values was observed (Fig.3), the LOA for aBMC was under 5% in white matter. Conclusion aBMC‐mcDESPOT is a practical MRI method for accurate determination of MWF within 6 min, offering unique opportunities to further integrate myelin imaging in clinical studies and trials.

Alzheimer s & DementiaVol. 20(S9)
National Institute on Aging (US)
Openalex Percentile: Top 58%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.