Analysis on improve the image quality of MRI machines based on technical factors

Magnetic Resonance Imaging (MRI) is a non-invasive technology which can produce three-dimensional image of issue. MRI is nowadays widely used to predict of diagnose a wide range of diseases. In this paper, it will be discussed that how can a balance reached among factors time of detection, Signal to Noise Ratio (SNR) and resolution to achieve a relatively best quality of MRI image. Independently, high SNR, high resolution and long-time can all benefit the image quality. However, the former two are inversely proportional to each other and the long-time of detection is beneficial for those two factors but lower the efficiency of diagnosis and the comfort of patients. As a result, it is found out that the time should be adjusted to an appropriate range, approximately in the medium stage of detection, and the resolution and SNR should neither be too high, which are both accurately depend on the practical condition. This paper can contribute to the quality improvement of MRI images as well as raise the efficiency of the process of MRI detection.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-01-01
DOI
https://doi.org/10.1049/icp.2024.3999
Primary Topic
Optical Systems and Laser Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis on improve the image quality of MRI machines based on technical factors

Mingyi Zhu
IET conference proceedings.
Optical Systems and Laser Technology
article

Analysis on improve the image quality of MRI machines based on technical factors

Mingyi Zhu
article en

Abstract

Magnetic Resonance Imaging (MRI) is a non-invasive technology which can produce three-dimensional image of issue. MRI is nowadays widely used to predict of diagnose a wide range of diseases. In this paper, it will be discussed that how can a balance reached among factors time of detection, Signal to Noise Ratio (SNR) and resolution to achieve a relatively best quality of MRI image. Independently, high SNR, high resolution and long-time can all benefit the image quality. However, the former two are inversely proportional to each other and the long-time of detection is beneficial for those two factors but lower the efficiency of diagnosis and the comfort of patients. As a result, it is found out that the time should be adjusted to an appropriate range, approximately in the medium stage of detection, and the resolution and SNR should neither be too high, which are both accurately depend on the practical condition. This paper can contribute to the quality improvement of MRI images as well as raise the efficiency of the process of MRI detection.

IET conference proceedings.Vol. 2024(19)
Nanjing Foreign Language School (CN)
Openalex Percentile: Top 100%
Optical Systems and Laser Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis on improve the image quality of MRI machines based on technical factors — Mingyi Zhu · IET conference proceedings. (2025) | TGRS Research Map | TGRS