Research and implementation of inverse time overcurrent protection algorithm for engine interface unit

The engine reverse thrust control is of great significance to the landing deceleration of the aircraft. The action time of inverse time overcurrent protection changes with the size of the current, and the protection of the upper and lower levels has a high adaptive ability, which can quickly cut out the fault near the power side. Compared with the stage current protection, it can better meet the dual requirements of quick movement and selectivity of the distribution network, and when the system operation mode changes, its selectivity and sensitivity will not change greatly. Aiming at the electrical characteristics of load and interface, an inverse time limit overcurrent protection method is proposed, which uses the protection mechanism of I2T curve theory. The inverse time limit current protection action time changes with the input current. When the input current exceeds the set threshold, the protection mechanism will be activated to achieve better protection performance.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-01-01
DOI
https://doi.org/10.1049/icp.2024.2846
Primary Topic
Engineering and Test Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research and implementation of inverse time overcurrent protection algorithm for engine interface unit

Wei Niu, Jinze Li, Yuan Liu
IET conference proceedings.
Engineering and Test Systems
article

Research and implementation of inverse time overcurrent protection algorithm for engine interface unit

Wei Niu, Jinze Li, Yuan Liu
article en

Abstract

The engine reverse thrust control is of great significance to the landing deceleration of the aircraft. The action time of inverse time overcurrent protection changes with the size of the current, and the protection of the upper and lower levels has a high adaptive ability, which can quickly cut out the fault near the power side. Compared with the stage current protection, it can better meet the dual requirements of quick movement and selectivity of the distribution network, and when the system operation mode changes, its selectivity and sensitivity will not change greatly. Aiming at the electrical characteristics of load and interface, an inverse time limit overcurrent protection method is proposed, which uses the protection mechanism of I2T curve theory. The inverse time limit current protection action time changes with the input current. When the input current exceeds the set threshold, the protection mechanism will be activated to achieve better protection performance.

IET conference proceedings.Vol. 2024(13)
Xi'an Aeronautical University (CN)
Openalex Percentile: Top 99%
Engineering and Test Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research and implementation of inverse time overcurrent protection algorithm for engine interface unit — Wei Niu, Jinze Li, et al. · IET conference proceedings. (2025) | TGRS Research Map | TGRS