Adaptive baud rate detection method for serial bus communication interface

The serial bus communication interface has the characteristics of convenient connection and simple protocol, such as RS232, RS422 and RS485, which are widely used in aerospace, security monitoring and other industrial fields. As one of the important parameters of serial bus communication interface, baud rate directly affects whether the data can be analysed correctly. According to the data frame protocol of serial bus communication interface, an adaptive baud rate detection method is proposed based on FPGA. By detecting the negative pulse width on the serial data line, the maximum common divisor of the negative pulse width is calculated, and the abnormal baud rate is continuously filtered from the candidate baud rate table according to the maximum common divisor, and finally the effective baud rate is output. The adaptive detection and matching of the baud rate are realized, and the flexibility and generality of the serial bus interface are significantly improved. Simulation results show the feasibility and effectiveness of the proposed method.

Authors

Publication Details

Journal
IET conference proceedings.
Published
2025-01-01
DOI
https://doi.org/10.1049/icp.2024.2948
Primary Topic
Embedded Systems and FPGA Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Adaptive baud rate detection method for serial bus communication interface

Xinming Fan, Jun Zhao, Panrang Qu, Jiang-Ping Wang
IET conference proceedings.
Embedded Systems and FPGA Applications
article

Adaptive baud rate detection method for serial bus communication interface

Xinming Fan, Jun Zhao, Panrang Qu, Jiang-Ping Wang
article en

Abstract

The serial bus communication interface has the characteristics of convenient connection and simple protocol, such as RS232, RS422 and RS485, which are widely used in aerospace, security monitoring and other industrial fields. As one of the important parameters of serial bus communication interface, baud rate directly affects whether the data can be analysed correctly. According to the data frame protocol of serial bus communication interface, an adaptive baud rate detection method is proposed based on FPGA. By detecting the negative pulse width on the serial data line, the maximum common divisor of the negative pulse width is calculated, and the abnormal baud rate is continuously filtered from the candidate baud rate table according to the maximum common divisor, and finally the effective baud rate is output. The adaptive detection and matching of the baud rate are realized, and the flexibility and generality of the serial bus interface are significantly improved. Simulation results show the feasibility and effectiveness of the proposed method.

IET conference proceedings.Vol. 2024(13)
Affordable and clean energy
Openalex Percentile: Top 100%
Embedded Systems and FPGA Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.