Effects of Different Voided Urine Sample Storage Time, Temperature, and Preservatives on Analysis with Multiplex Bead-Based Oncuria Bladder Cancer Immunoassay

<b>Background/Objectives:</b> Urinalysis accuracy requires reliable sample stability that is dependent on the chosen collection and storage conditions. The multiplex Oncuria bladder cancer immunoassay currently needs urine samples stored at 4 °C until analysis, which requires more effort, equipment, and workflow than storing samples at room temperature. Thus, successful sample storage at room temperature (20 °C) may reduce laboratory handling time and expenses. This study evaluated whether different voided urine sample collection and storage parameters affected subsequent biomarker analysis with Oncuria. The Oncuria simultaneously quantifies 10 protein analytes in urine to generate a bladder cancer diagnostic signature. <b>Methods</b>: Samples were stored at varied temperatures (20 °C, 4 °C, -20 °C) for up to 1 month. The effects of adding two commercial urine sample stabilizers and antibiotics (trimethoprim) were also assessed. Subsequently, multiple potential biospecimen stabilizers were tested in urine samples and evaluated with Oncuria in hopes of allowing the urine sample to remain at room temperature for extended periods of time. <b>Results</b>: First, it was demonstrated that voided urine samples stored at room temperate without such stabilizers had different levels of the 10 analytes associated with the Oncuria test compared to voided urine samples stored at 4 °C. Next, we evaluated the effects of commercially available biospecimen stabilizers. Despite the addition of these stabilizers, the levels of the 10 analytes were altered when the samples were stored at room temperature for prolonged periods of time. Therefore, we could not identify a suitable biospecimen stabilizer that would not require sample refrigeration. <b>Conclusions</b>: To minimize sample degradation/alteration after collection, voided urine samples should be refrigerated until analyzed with Oncuria as the refrigeration is advantageous for the storage and the transport of these urine samples.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2025-01-09
DOI
https://doi.org/10.3390/diagnostics15020138
Citations
2
Primary Topic
Photodynamic Therapy Research Studies
Type
article
Field-Weighted Citation Impact
3.04

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Different Voided Urine Sample Storage Time, Temperature, and Preservatives on Analysis with Multiplex Bead-Based Oncuria Bladder Cancer Immunoassay

Wayne Hogrefe, Charles J. Rosser, Riko Lee, Toru Sakatani et al.
2 citations
Diagnostics
Photodynamic Therapy Research Studies
3.04
article

Effects of Different Voided Urine Sample Storage Time, Temperature, and Preservatives on Analysis with Multiplex Bead-Based Oncuria Bladder Cancer Immunoassay

Wayne Hogrefe, Charles J. Rosser, Riko Lee, Toru Sakatani, Hideki Furuya, Sunao Tanaka, Kaoru Murakami, Fernando Siguencia
article en
2 citations

Abstract

<b>Background/Objectives:</b> Urinalysis accuracy requires reliable sample stability that is dependent on the chosen collection and storage conditions. The multiplex Oncuria bladder cancer immunoassay currently needs urine samples stored at 4 °C until analysis, which requires more effort, equipment, and workflow than storing samples at room temperature. Thus, successful sample storage at room temperature (20 °C) may reduce laboratory handling time and expenses. This study evaluated whether different voided urine sample collection and storage parameters affected subsequent biomarker analysis with Oncuria. The Oncuria simultaneously quantifies 10 protein analytes in urine to generate a bladder cancer diagnostic signature. <b>Methods</b>: Samples were stored at varied temperatures (20 °C, 4 °C, -20 °C) for up to 1 month. The effects of adding two commercial urine sample stabilizers and antibiotics (trimethoprim) were also assessed. Subsequently, multiple potential biospecimen stabilizers were tested in urine samples and evaluated with Oncuria in hopes of allowing the urine sample to remain at room temperature for extended periods of time. <b>Results</b>: First, it was demonstrated that voided urine samples stored at room temperate without such stabilizers had different levels of the 10 analytes associated with the Oncuria test compared to voided urine samples stored at 4 °C. Next, we evaluated the effects of commercially available biospecimen stabilizers. Despite the addition of these stabilizers, the levels of the 10 analytes were altered when the samples were stored at room temperature for prolonged periods of time. Therefore, we could not identify a suitable biospecimen stabilizer that would not require sample refrigeration. <b>Conclusions</b>: To minimize sample degradation/alteration after collection, voided urine samples should be refrigerated until analyzed with Oncuria as the refrigeration is advantageous for the storage and the transport of these urine samples.

DiagnosticsVol. 15(2)
Cedars-Sinai Medical Center (US), Nonagen Bioscience (United States) (US)
Cedars-Sinai Medical Center, National Institutes of Health, National Cancer Institute
Openalex Percentile: Top 12%
Photodynamic Therapy Research Studies
3.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.