The parameter sensitivity analysis on the dynamic stiffness of the electro-hydrostatic actuator

The electro-hydrostatic actuator (EHA) has the advantage of high power weight ratio, less leakage and the absence of throttle loss. It’s used on the multi-electric aircraft and the all-electric aircraft. However, it will be affected by the aerodynamic load and the rudder flutter will occur if the dynamic stiffness of the EHA is low. As a result, it’s significant to analyse the sensitivity of the EHA’s parameters on the dynamic stiffness. The article builds a linear model of the EHA considering the leakage in the system. What’s more, the local parameter sensitivity for the dynamic stiffness is calculated when the frequency is between 0.01 Hz and 1000 Hz.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-01-01
DOI
https://doi.org/10.1049/icp.2024.3268
Primary Topic
Hydraulic and Pneumatic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The parameter sensitivity analysis on the dynamic stiffness of the electro-hydrostatic actuator

Bing Chu, Yang Yu-liang, Shuai Wu, Wei Renlei et al.
IET conference proceedings.
Hydraulic and Pneumatic Systems
article

The parameter sensitivity analysis on the dynamic stiffness of the electro-hydrostatic actuator

Bing Chu, Yang Yu-liang, Shuai Wu, Wei Renlei, Luo Jianing
article en

Abstract

The electro-hydrostatic actuator (EHA) has the advantage of high power weight ratio, less leakage and the absence of throttle loss. It’s used on the multi-electric aircraft and the all-electric aircraft. However, it will be affected by the aerodynamic load and the rudder flutter will occur if the dynamic stiffness of the EHA is low. As a result, it’s significant to analyse the sensitivity of the EHA’s parameters on the dynamic stiffness. The article builds a linear model of the EHA considering the leakage in the system. What’s more, the local parameter sensitivity for the dynamic stiffness is calculated when the frequency is between 0.01 Hz and 1000 Hz.

IET conference proceedings.Vol. 2024(13)
Shenyang Aerospace University (CN), Ningbo University of Technology (CN), Beihang University (CN), Ministry of Industry and Information Technology (CN)
Openalex Percentile: Top 99%
Hydraulic and Pneumatic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.