Effect of insect net on the response performance of point type photoelectric smoke detectors

As detection technology advances, facilities that require early fire detection, such as energy storage power plants and airline cargo compartments, require fire detectors to respond at ever-increasing speeds. To address the hysteresis phenomenon of smoke detectors in the process of fire detection, this paper starts from the structure of the detector's insect net and carries out an experimental study in the standard smoke box to explore the influence of the insect net on the response performance of point-type photoelectric smoke detectors under different maximum obscurity. The experimental results show that the insect net impedes the flow of smoke, reduces the output signal of the detector, increases the hysteresis time of the smoke detector, and the detector response is advanced by 27-48s when there is no insect net, and this hysteresis phenomenon is more obvious when the smoke concentration is lower. This provides the basis and method for the selection and design of the photoelectric smoke detector.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-01-01
DOI
https://doi.org/10.1049/icp.2024.3058
Primary Topic
Fire Detection and Safety Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of insect net on the response performance of point type photoelectric smoke detectors

Song Lu, Shaonan Liu, Xiaoyue Li, Heping Zhang et al.
IET conference proceedings.
Fire Detection and Safety Systems
article

Effect of insect net on the response performance of point type photoelectric smoke detectors

Song Lu, Shaonan Liu, Xiaoyue Li, Heping Zhang, Chenran Ruan
article en

Abstract

As detection technology advances, facilities that require early fire detection, such as energy storage power plants and airline cargo compartments, require fire detectors to respond at ever-increasing speeds. To address the hysteresis phenomenon of smoke detectors in the process of fire detection, this paper starts from the structure of the detector's insect net and carries out an experimental study in the standard smoke box to explore the influence of the insect net on the response performance of point-type photoelectric smoke detectors under different maximum obscurity. The experimental results show that the insect net impedes the flow of smoke, reduces the output signal of the detector, increases the hysteresis time of the smoke detector, and the detector response is advanced by 27-48s when there is no insect net, and this hysteresis phenomenon is more obvious when the smoke concentration is lower. This provides the basis and method for the selection and design of the photoelectric smoke detector.

IET conference proceedings.Vol. 2024(13)
University of Science and Technology of China (CN), Commercial Aircraft Corporation of China (China) (CN)
Openalex Percentile: Top 99%
Fire Detection and Safety Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines